EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

In‐vivo repeatability of three intra‐oral spectrophotometers

Vincent Hampé-Kautz, Tatiana Roman iD, Thibault Schwob, Bérangère Cournault, Olivier Etienne iD

Journal of Esthetic and Restorative Dentistry · 2024-03 · 36 (3) · 520-526

DOI: 10.1111/jerd.13182 ↗

At a glance

Journal article in Journal of Esthetic and Restorative Dentistry, published online on 2024-01-03. Written by Vincent Hampé-Kautz and 4 co-authors. Institution: Robert Frank Dental Faculty, University of Strasbourg, Strasbourg, France. Major MEDLINE topics: Prosthesis Coloring, Tooth. Cited 14 times so far (Crossref); 34 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

The objective was to assess the repeatability of three spectrophotometers, based on the CIELCh factors and shadeguide reference measurements. Materials and Methods Color analysis was performed using three devices: Rayplicker, Easyshade 4, and Easyshade V. Five repeated measures were performed by the same operator, on the right central maxillary incisor of 30 patients. The CIELCh factors were retrieved and the intra‐class correlation was calculated. The Vita Classical and Vita 3D Master shadeguides were used to evaluate the respective Fleiss' Kappa factors.

Results

Rayplicker and Easyshade V demonstrated strong intra‐class correlation based on the CIELCh factors: 0.98, 0.99, and 0.91 for Rayplicker, and 0.95, 0.99, and 0.93 for Easyshade V, for the L *, C *, and h * parameters, respectively. Regarding the repeatability of the shadeguide data, while Easyshade 4 had the best repeatability when using the Vita Classical as a reference, Rayplicker and Easyshade V showed better repeatability when using the Vita 3D Master.

Conclusion

These findings suggest that both Rayplicker and Easyshade V are reliable devices for measuring CIELCh parameters. In terms of shadeguide references, the reliability of spectrophotometers is generally lower compared to the CIELCh measurements. Clinical Significance Given their good repeatability, both the Rayplicker and the Easyshade V spectrophotometers are reliable tools for prosthetic dental practices.

Subjects

MeSH terms (MEDLINE)

Prosthesis ColoringToothHumansReproducibility of ResultsColorSpectrophotometry

Author keywords

L* C* h*Rayplickerrepeatabilityshade analysisspectrophotometer

Authors and institutions

  • Robert Frank Dental Faculty, University of Strasbourg, Strasbourg, France.
  • INSERM U1121, Strasbourg, France.
  • Icube UMR7357, Strasbourg, France.

ORCID profiles: Tatiana Roman, Olivier Etienne

Cite

APA

Hampé-Kautz, V., Roman, T., Schwob, T., Cournault, B., & Etienne, O. (2024). In‐vivo repeatability of three intra‐oral spectrophotometers. Journal of Esthetic and Restorative Dentistry, 36(3), 520-526. https://doi.org/10.1111/jerd.13182

Vancouver

Hampé-Kautz V, Roman T, Schwob T, Cournault B, Etienne O. In‐vivo repeatability of three intra‐oral spectrophotometers. Journal of Esthetic and Restorative Dentistry. 2024;36(3):520-526. doi:10.1111/jerd.13182

BibTeX
@article{HampKautz2024,
  author = {Hampé-Kautz, Vincent and Roman, Tatiana and Schwob, Thibault and Cournault, Bérangère and Etienne, Olivier},
  title = {In‐vivo repeatability of three intra‐oral spectrophotometers},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2024},
  volume = {36},
  number = {3},
  pages = {520--526},
  doi = {10.1111/jerd.13182}
}
Start for free →