Comparative Analysis of Safety Profiles of Pulsed Field and Thermal Energy Atrial Fibrillation Ablation: Insight From the Multicenter Real‐World Ablation Registry
Journal of Cardiovascular Electrophysiology · 2026-11 · 37 (11) · 2601-2612
DOI: 10.1111/jce.70474 ↗At a glance
Multizentrische Studie in Journal of Cardiovascular Electrophysiology, published online on 2026-08-05. Written by Osamu Inaba and 14 co-authors. Institution: Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan. Major MEDLINE topics: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation. Cited 1 times so far (Crossref); 30 references.
Abstract (original language)
Background
Beginning in September 2024, three large‐footprint pulsed‐field ablation (PFA) systems were introduced in Japan for atrial fibrillation (AF) ablation.
Objective
To compare acute procedural outcomes and safety profiles between PFA and thermal ablation.
Methods
This multi‐center observational study included 4969 consecutive index AF ablation procedures (69 ± 11 years, 1495 women, 2705 paroxysmal) performed between January 2024 and July 2025. Among them, 2817 and 2152 procedures were performed with thermal ablation and PFA (FARAPULSE 53.3%, PulseSelect 41.3%, and VARIPULSE 5.5%), respectively.
Results
PFA procedures were performed under deeper sedation (70.5% deep sedation) compared with thermal ablation. The total PFA application numbers were 50 ± 13 for FARAPULSE, 49 ± 13 for PulseSelect, and 24 ± 8.5 for VARIPULSE. Touch‐up ablation for pulmonary veins was more frequently required with balloon‐based thermal ablation than with PFA (7.2% vs. 1.5%, p < 0.01). Adjunctive posterior wall isolation was more common in the PFA‐group than Thermal‐group (30.3% vs. 11.4%, p < 0.01). Fluoroscopy time was significantly longer (27.8 ± 17.1 vs. 24.9 ± 17.6 min, p < 0.01) and total procedure time significantly shorter in the PFA‐group than Thermal‐group (106 ± 48.5 vs. 131 ± 54.4 min, p < 0.01). The overall complication rate (2.4% vs. 4.4%, p < 0.01) and phrenic nerve palsy rate (0.1% vs. 1.5%, p < 0.01) were significantly lower, while coronary spasms tended to be more frequent in the PFA‐group. No gastric hypomotility or pericarditis occurred in the PFA‐group despite much lower use of esophageal temperature monitoring (3.2% vs. 83.1%, p < 0.01).
Conclusions
This large real‐world registry demonstrated a significantly lower incidence of procedure‐related complications with large‐footprint PFA devices compared with thermal ablation systems, despite early‐phase adoption.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan.
- Department of Cardiovascular Medicine, Institute of Science Tokyo, Tokyo, Japan.
- Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
- Department of Cardiology, Yokosuka Kyosai Hospital, Kanagawa, Japan.
- Department of Cardiology, NHO Disaster Medical Center, Tokyo, Japan.
- Department of Cardiology, Japanese Red Cross Musashino Hospital, Tokyo, Japan.
ORCID profiles: Shinsuke Miyazaki, Yasuteru Yamauchi, Akira Mizukami
Cite
APA
Inaba, O., Miyazaki, S., Nitta, J., Takahashi, A., Yamashita, S., Nagata, Y., Iwai, S., Takahashi, Y., Yamauchi, Y., Mizukami, A., Hachiya, H., Suzuki, A., Hayashi, Y., Negishi, M., & Sasano, T. (2026). Comparative Analysis of Safety Profiles of Pulsed Field and Thermal Energy Atrial Fibrillation Ablation: Insight From the Multicenter Real‐World Ablation Registry. Journal of Cardiovascular Electrophysiology, 37(11), 2601-2612. https://doi.org/10.1111/jce.70474
Vancouver
Inaba O, Miyazaki S, Nitta J, Takahashi A, Yamashita S, Nagata Y, et al. Comparative Analysis of Safety Profiles of Pulsed Field and Thermal Energy Atrial Fibrillation Ablation: Insight From the Multicenter Real‐World Ablation Registry. Journal of Cardiovascular Electrophysiology. 2026;37(11):2601-2612. doi:10.1111/jce.70474
BibTeX
@article{Inaba2026,
author = {Inaba, Osamu and Miyazaki, Shinsuke and Nitta, Junichi and Takahashi, Atsushi and Yamashita, Shu and Nagata, Yasutoshi and Iwai, Shinsuke and Takahashi, Yoshihide and Yamauchi, Yasuteru and Mizukami, Akira and Hachiya, Hitoshi and Suzuki, Atsushi and Hayashi, Yosuke and Negishi, Miho and Sasano, Tetsuo},
title = {Comparative Analysis of Safety Profiles of Pulsed Field and Thermal Energy Atrial Fibrillation Ablation: Insight From the Multicenter Real‐World Ablation Registry},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
volume = {37},
number = {11},
pages = {2601--2612},
doi = {10.1111/jce.70474}
}
EUVIMED