EUVIMEDEUVIMED entdecken
Vergleichsstudie

Multicatheter Comparison of Very High‐Power Short‐Duration Radiofrequency Ablation Lesions

Samual Turnbull iD, Michael A Barry, Timothy G Campbell, Kasun De Silva, Ashwin Bhaskaran, Pierre Qian iD, Eddy Kizana, Saurabh Kumar

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70421 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Samual Turnbull und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Westmead Hospital, Westmead, New South Wales, Australia. Hauptthemen laut MEDLINE: Catheter Ablation, Pulmonary Veins, Cardiac Catheters. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Heart Foundation Vanguard Grant, Research and Education Network.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Very high‐power short‐duration (vHPSD) radiofrequency ablation (RFA) is an alternative strategy for pulmonary vein isolation. However, rapid temperature rises may cause complications. The QDOT Micro is designed to detect temperature rises for automatic power and irrigation flow adjustments. We compared how differences in ablation electrode design between three RFA catheters impact vHPSD lesions. Methods vHPSD RFA was performed within a validated gel tank model. Four‐second ablations were delivered with stable contact force using the QDOT, SmartTouch, and TactiFlex SE at 60, 70, 80, and 90 watts, positioned perpendicular (90°), oblique (45°), and parallel (0°) to the ablation target, utilizing 0.9% and 0.45% “half‐normal” saline (HNS) irrigation. The SmartTouch and TactiFlex were operated in power‐controlled mode, and each configuration was repeated three times, with images captured every second to characterize lesions.

Results

In total, 216 vHPSD lesions were delivered. At 90 W, 90°, and 0.9% saline, the QDOT produced lesions with a mean depth of 1.93 mm. The TactiFlex produced shallower lesions, with a mean depth of 1.88 mm ( p = 0.02), and the SmartTouch produced the deepest, with a mean depth of 2.37 mm ( p < 0.001). The mean diameter of QDOT lesions, at 4.63 mm, was comparable to TactiFlex lesions (4.58 mm, p = 0.8), whilst the SmartTouch lesions were significantly wider than both the QDOT and TactiFlex (6.04 mm, p < 0.001). Steam‐pop risk, based on lesion temperature, was lowest for the TactiFlex. Conclusion vHPSD lesions produced with the QDOT achieved greater dimensions and temperatures than those with the TactiFlex under controlled conditions, suggesting a difference in the cooling profile of the ablation electrodes. vHPSD with the SmartTouch or 0.45% HNS are likely to increase the risk of steam pops.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationPulmonary VeinsCardiac CathetersTime FactorsEquipment DesignTherapeutic IrrigationHumans

Stichwörter der Autor:innen

atrial fibrillationcatheter ablationcatheter comparisonhigh‐power short durationirrigated ablationpulmonary vein isolation

Autor:innen und Institutionen

  • Department of Cardiology, Westmead Hospital, Westmead, New South Wales, Australia.
  • Westmead Applied Research Centre, University of Sydney, Sydney, New South Wales, Australia.
  • Westmead Institute for Medical Research, University of Sydney, Sydney, New South Wales, Australia.

ORCID-Profile: Samual Turnbull, Pierre Qian

Förderung

  • National Heart Foundation Vanguard Grant
  • Research and Education Network

Zitieren

APA

Turnbull, S., Barry, M. A., Campbell, T. G., Silva, K., Bhaskaran, A., Qian, P., Kizana, E., & Kumar, S. (2026). Multicatheter Comparison of Very High‐Power Short‐Duration Radiofrequency Ablation Lesions. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70421

Vancouver

Turnbull S, Barry MA, Campbell TG, Silva K, Bhaskaran A, Qian P, et al. Multicatheter Comparison of Very High‐Power Short‐Duration Radiofrequency Ablation Lesions. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70421

BibTeX
@article{Turnbull2026,
  author = {Turnbull, Samual and Barry, Michael A and Campbell, Timothy G and Silva, Kasun De and Bhaskaran, Ashwin and Qian, Pierre and Kizana, Eddy and Kumar, Saurabh},
  title = {Multicatheter Comparison of Very High‐Power Short‐Duration Radiofrequency Ablation Lesions},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70421}
}
Kostenlos starten →