Short‐Term Procedural Outcomes of Posterior Wall Isolation Using the Affera Pulse Field Ablation System
Journal of Cardiovascular Electrophysiology · 2026
DOI: 10.1111/jce.70261 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Udit Thakur und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Royal Melbourne Hospital, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation, Heart Rate. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Health and Medical Research Council (NHMRC), National Heart Foundation research scholarship., Biosense Webster and Medtronic.
Abstract (Originalsprache)
Background
Posterior wall isolation (PWI) is often added to pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) and at redo ablation. Still, procedural performance with the Affera pulsed field ablation (PFA) platform is not well described.
Methods
We retrospectively analyzed consecutive patients who underwent PWI with the Affera Sphere‐9 lattice‐tip catheter from April to August 2025. Baseline characteristics and procedural data, including PWI time, number of lesions, and acute success, were analyzed. The primary procedural endpoint was acute PWI success. Secondary measures included time to PWI, number of applications, posterior wall area isolated, and complications.
Results
Forty patients underwent PWI (paroxysmal AF 13 [32.5%], persistent AF 27 [67.5%]). First pass PWI was achieved in 97.5%; overall acute PWI success was 100%. Median time to complete PWI was 7.0 min (IQR 5.1–11.0). Mean lesions for PWI were 19.6 ± 6.6, and the mean posterior wall area isolated was 12.9 ± 4.5 cm². Two minor vascular complications occurred (5.0%): one acute and one delayed femoral hematoma, both managed conservatively. After a median follow‐up of 76 [58.5–121] days, 38/40 (95%) patients remained free from atrial arrhythmia.
Conclusions
PWI with the Affera Sphere‐9 system achieved 97.5% first‐pass isolation with rapid, consistent procedural times. Further study of lesion durability and clinical outcomes is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Royal Melbourne Hospital, Melbourne, Victoria, Australia.
- Department of Medicine, University of Melbourne, Melbourne, Victoria, Australia.
- Baker IDI Heart & Diabetes Institute, Melbourne, Victoria, Australia.
- Heart Centre, Alfred Hospital, Melbourne, Victoria, Australia.
ORCID-Profile: Udit Thakur, Souvik Kumar Das, Peter M Kistler, Jonathan M Kalman, Robert Anderson
Förderung
- National Health and Medical Research Council (NHMRC)
- National Heart Foundation research scholarship.
- Biosense Webster and Medtronic
Zitieren
APA
Thakur, U., Junker, J., Koh, Y., Virk, S., Kumar Das, S., Liang, D., Pathik, B., Sparks, P. B., McLellan, A., Morton, J., Lee, G., Al-Kaisey, A., Kistler, P. M., Kalman, J. M., & Anderson, R. (2026). Short‐Term Procedural Outcomes of Posterior Wall Isolation Using the Affera Pulse Field Ablation System. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70261
Vancouver
Thakur U, Junker J, Koh Y, Virk S, Kumar Das S, Liang D, et al. Short‐Term Procedural Outcomes of Posterior Wall Isolation Using the Affera Pulse Field Ablation System. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70261
BibTeX
@article{Thakur2026,
author = {Thakur, Udit and Junker, Jasper and Koh, Youlin and Virk, Sohaib and Kumar Das, Souvik and Liang, Danlu and Pathik, Bhupesh and Sparks, Paul B and McLellan, Alex and Morton, Joseph and Lee, Geoffrey and Al-Kaisey, Ahmed and Kistler, Peter M and Kalman, Jonathan M and Anderson, Robert},
title = {Short‐Term Procedural Outcomes of Posterior Wall Isolation Using the Affera Pulse Field Ablation System},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
doi = {10.1111/jce.70261}
}
EUVIMED