EUVIMEDOpdag EUVIMED
VergleichsstudieOpen access

Sex and Age Differences in Procedural and Medium‐Term Electrical Performance Outcomes of Dual‐Chamber Leadless Pacemakers

Kaiyu Jia iD, Felicia Zhang, Arun Gajan Pradeep, Elizabeth Rimsky iD, Samer Saouma, Rina Shah, Philippe Akhrass, Marcin Kowalski, Valay Parikh

Journal of Cardiovascular Electrophysiology · 2026-08 · 37 (8) · 1765-1774

DOI: 10.1111/jce.70407 ↗

At a glance

Vergleichsstudie in Journal of Cardiovascular Electrophysiology, published online on 2026-06-15. Written by Kaiyu Jia and 8 co-authors. Institution: Northwell Health, New Hyde Park, New York, USA. Major MEDLINE topics: Pacemaker, Artificial, Cardiac Pacing, Artificial, Heart Rate, Arrhythmias, Cardiac. 20 references. The full text is freely available in PubMed Central.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Studies regarding sex and age differences in clinical outcomes of DCLP patients remain limited.

Methods

This was a retrospective, single‐center study, which evaluated the consecutive patients who underwent Aveir DCLP implantation between January 2024 and September 2025. The included patients were divided into two groups based on sex or age. Procedural outcomes and device performance at implantation, at 1st follow‐up between 1 and 3 months, at 2nd follow‐up between 3 and 6 months, and at 3rd follow‐up between 6 and 12 months were evaluated.

Results

A total of 151 patients were included. Among them, 66 patients (43.7%) were female, and 49 (32.5%) patients were younger than 75 years old. For comparison between sexes, female patients had higher ventricular impedance (782.55 ± 279.26 vs. 687.85 ± 268.07 Ω, p = 0.029) at the time of implant. Female patients also had lower atrial sensing compared to their male counterparts at 1st and 2nd follow up. For comparison between patients who were < 75 years old and > =75 years old, at 3rd follow up, atrial sensing is lower in patients of 75 years and older (3.69 ± 1.02 vs. 2.86 ± 1.83 mV, p = 0.022). There was no significant difference in procedural outcomes between different sex and age groups.

Conclusion

There were no clinically significant differences regarding post‐procedural complications and electrical parameters between different ages and sexes. These findings from real‐life study are reassuring to support wider utilization of these devices.

Subjects

MeSH terms (MEDLINE)

Pacemaker, ArtificialCardiac Pacing, ArtificialHeart RateArrhythmias, CardiacHumansFemaleRetrospective StudiesAge FactorsAgedTime FactorsSex FactorsMaleTreatment OutcomeProsthesis DesignMiddle AgedRisk FactorsAction PotentialsAged, 80 and over

Author keywords

agedual‐chamber leadless pacemakerelectrical performanceprocedural outcomessex

Authors and institutions

  • Northwell Health, New Hyde Park, New York, USA.
  • Cardiovascular Institute, Northwell Health, New Hyde Park, New York, USA.
  • Department of Internal Medicine, Staten Island University Hospital, Northwell Health, Staten Island, New York, USA.
  • Department of Cardiology, Staten Island University Hospital, New York.

ORCID profiles: Kaiyu Jia, Elizabeth Rimsky

Cite

APA

Jia, K., Zhang, F., Pradeep, A. G., Rimsky, E., Saouma, S., Shah, R., Akhrass, P., Kowalski, M., & Parikh, V. (2026). Sex and Age Differences in Procedural and Medium‐Term Electrical Performance Outcomes of Dual‐Chamber Leadless Pacemakers. Journal of Cardiovascular Electrophysiology, 37(8), 1765-1774. https://doi.org/10.1111/jce.70407

Vancouver

Jia K, Zhang F, Pradeep AG, Rimsky E, Saouma S, Shah R, et al. Sex and Age Differences in Procedural and Medium‐Term Electrical Performance Outcomes of Dual‐Chamber Leadless Pacemakers. Journal of Cardiovascular Electrophysiology. 2026;37(8):1765-1774. doi:10.1111/jce.70407

BibTeX
@article{Jia2026,
  author = {Jia, Kaiyu and Zhang, Felicia and Pradeep, Arun Gajan and Rimsky, Elizabeth and Saouma, Samer and Shah, Rina and Akhrass, Philippe and Kowalski, Marcin and Parikh, Valay},
  title = {Sex and Age Differences in Procedural and Medium‐Term Electrical Performance Outcomes of Dual‐Chamber Leadless Pacemakers},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {8},
  pages = {1765--1774},
  doi = {10.1111/jce.70407}
}
Start for free →