EUVIMEDEUVIMED entdecken
Open Access

Mental Disorders After Cardiac Implantable Electronic Device Implantation in Young Individuals

Young-Hae Go iD, Chan Soon Park iD, Bongseong Kim iD, Soongu Kwak iD, Tae-Min Rhee, Hyung-Kwan Kim iD, Yong-Jin Kim, Kyungdo Han, Heesun Lee iD, Jun-Bean Park iD

Journal of the American Heart Association · 07.07.2026 · 15 (13)

DOI: 10.1161/jaha.125.046715 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Heart Association, erschienen am 07.07.2026. Verfasst von Young-Hae Go und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine Seoul National University College of Medicine Seoul Republic of Korea. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial, Mental Disorders. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Increasing use of cardiac implantable electronic devices (CIEDs) has raised concerns about psychological distress in young adults. We evaluated the risk of incident mental disorders after CIED implantation.

Methods

Using the Korean National Health Insurance database, we identified individuals aged 20 to 39 years who underwent health checkups in 2009 to 2012. Those receiving a new CIED within 4 years were included, and controls were selected by 1:5 matching for age, sex, and index year. The primary outcome was a composite of newly diagnosed mental disorders (mood disorders and anxiety/stress‐related/somatoform disorders), and secondary outcomes were the individual components.

Results

There were 569 CIED recipients (209 pacemakers, 360 implantable cardioverter‐defibrillators) and 2821 matched controls analyzed. Over a median follow‐up of 5.3 years, both the pacemaker and implantable cardioverter‐defibrillator implantations were associated with a significantly higher risk of the primary outcome compared with no device (hazard ratio [HR], 1.63 [95% CI, 1.20–2.21] and HR, 1.80 [95% CI, 1.39–2.35], respectively). In head‐to‐head analyses, the risk of the primary outcome did not differ significantly between implantable cardioverter‐defibrillator and pacemaker recipients (adjusted HR, 1.09 [95% CI, 0.75–1.59]). Risks of secondary outcomes were also increased in both device groups. CIED recipients had a 1.95‐fold higher risk of mental disorders within 2 years postimplantation (95% CI, 1.45–2.62), and this elevated risk persisted beyond 2 years (HR, 1.54 [95% CI, 1.13–2.11]).

Conclusions

Among young individuals, both pacemaker and implantable cardioverter‐defibrillator implantations were associated with increased risks of mental disorders, supporting proactive psychological screening and interventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialMental DisordersHumansFemaleMaleRepublic of KoreaAdultYoung AdultRisk FactorsIncidenceTime FactorsRisk AssessmentDatabases, FactualAge FactorsRetrospective Studies

Stichwörter der Autor:innen

anxiety disorderscardiologymental healthmood disorders

Autor:innen und Institutionen

  • Department of Internal Medicine Seoul National University College of Medicine Seoul Republic of Korea.
  • Division of Cardiology, Cardiovascular Center Seoul National University Hospital Seoul Republic of Korea.
  • Division of Cardiology, Department of Internal Medicine Asan Medical Center, University of Ulsan College of Medicine Seoul Republic of Korea.
  • Department of AI-Bio, Graduate School of AI Soongsil University Seoul South Korea.
  • Division of Cardiology, Department of Internal Medicine Seoul National University Hospital Healthcare System Gangnam Center Seoul Republic of Korea.
  • Department of Statistics and Actuarial Science Soongsil University Seoul Republic of Korea.

ORCID-Profile: Young-Hae Go, Chan Soon Park, Bongseong Kim, Soongu Kwak, Hyung-Kwan Kim, Heesun Lee, Jun-Bean Park

Zitieren

APA

Go, Y. H., Park, C. S., Kim, B., Kwak, S., Rhee, T. M., Kim, H. K., Kim, Y. J., Han, K., Lee, H., & Park, J. B. (2026). Mental Disorders After Cardiac Implantable Electronic Device Implantation in Young Individuals. Journal of the American Heart Association, 15(13). https://doi.org/10.1161/jaha.125.046715

Vancouver

Go YH, Park CS, Kim B, Kwak S, Rhee TM, Kim HK, et al. Mental Disorders After Cardiac Implantable Electronic Device Implantation in Young Individuals. Journal of the American Heart Association. 2026;15(13). doi:10.1161/jaha.125.046715

BibTeX
@article{Go2026,
  author = {Go, Young-Hae and Park, Chan Soon and Kim, Bongseong and Kwak, Soongu and Rhee, Tae-Min and Kim, Hyung-Kwan and Kim, Yong-Jin and Han, Kyungdo and Lee, Heesun and Park, Jun-Bean},
  title = {Mental Disorders After Cardiac Implantable Electronic Device Implantation in Young Individuals},
  journal = {Journal of the American Heart Association},
  year = {2026},
  volume = {15},
  number = {13},
  doi = {10.1161/jaha.125.046715}
}
Kostenlos starten →