EUVIMEDObjevte EUVIMED
Multizentrische StudieVergleichsstudieOpen access · CC BY 4.0

Comparison of Two Pulsed Field Ablation Systems for Atrial Fibrillation: One‐Year Outcomes From a Multicenter Registry

Marisa van der Graaf iD, Bob G S Abeln, Jippe C Balt, Suneet Mittal, Bradley P Knight, Melanie A Gunawardene iD, Bradley Wilsmore, Amardeep Amardeep, Tim Harloff, Max Liebregts iD, Michael M Malaty, Dan L Musat and 7 more

Journal of Cardiovascular Electrophysiology · 2026-07 · 37 (7) · 1522-1532

DOI: 10.1111/jce.70375 ↗

At a glance

Multizentrische Studie in Journal of Cardiovascular Electrophysiology, published online on 2026-05-26. Written by Marisa van der Graaf and 18 co-authors. Institution: Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands. Major MEDLINE topics: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation, Cardiac Catheters. 31 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

While various pulsed field ablation (PFA) systems for atrial fibrillation (AF) ablation have become available in recent years, data comparing long‐term efficacy outcomes remain limited.

Purpose

To compare long‐term efficacy outcomes of two commercially available PFA systems to perform pulmonary vein isolation (PVI) for AF in a multicenter clinical setting.

Methods

We conducted an international, multicenter, registry study of patients with AF undergoing a first ablation between January 29, 2024, and September 1, 2024. Patients were treated with either the pentaspline catheter or the circular over‐the‐wire catheter in all centers. Endpoints included time to recurrence of atrial arrhythmias following a 2‐month blanking period and repeat ablation outcomes. Factors associated with recurrence were assessed.

Results

A total of 428 patients were included, of whom 231 (54.0%) were treated with the pentaspline catheter. Most patients (84.6%) underwent a PVI‐only procedure, with significantly longer procedure and LA dwell times observed in the circular catheter group ( p < 0.001). Acute procedural success was achieved in all patients. At 12 months, AF‐recurrence was observed in 33.5% of patients overall, with similar rates between groups (pentaspline catheter 34.1% vs. circular catheter 32.8% [log‐rank p = 0.93]). A longer time since AF diagnosis and persistent AF were associated with recurrence of AF. Repeat ablation was performed in 14.9% of patients.

Conclusion

In this study, we compared two commercially available PFA systems for primary PVI in AF patients. Both achieved high acute success and similar 12‐month AF recurrence rates, indicating comparable efficacy.

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationPulmonary VeinsCatheter AblationCardiac CathetersHumansRegistriesTime FactorsFemaleMaleRecurrenceMiddle AgedAgedEquipment DesignRisk FactorsHeart RateAction PotentialsTreatment OutcomeIrreversible Electroporation Therapy

Author keywords

atrial fibrillationlong‐term efficacypulmonary vein isolationpulsed field ablation

Authors and institutions

  • Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands.
  • Department of Cardiology, Amsterdam UMC, Amsterdam, the Netherlands.
  • Snyder Center for Comprehensive Atrial Fibrillation, Valley Health System, Paramus, New Jersey, USA.
  • Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.
  • Department of Cardiology and Intensive Care Medicine, Asklepios St. Georg Clinic, Hamburg, Germany.
  • Department of Cardiology, John Hunter Hospital, New Lambton, New South Wales, Australia.

ORCID profiles: Marisa van der Graaf, Melanie A Gunawardene, Max Liebregts, Nishant Verma

Cite

APA

van der Graaf, M., Abeln, B. G. S., Balt, J. C., Mittal, S., Knight, B. P., Gunawardene, M. A., Wilsmore, B., Amardeep, A., Harloff, T., Liebregts, M., Malaty, M. M., Musat, D. L., Peigh, G., Singh, S., Wijffels, M. C. E. F., Willems, S., Verma, N., van Dijk, V. F., & Boersma, L. V. A. (2026). Comparison of Two Pulsed Field Ablation Systems for Atrial Fibrillation: One‐Year Outcomes From a Multicenter Registry. Journal of Cardiovascular Electrophysiology, 37(7), 1522-1532. https://doi.org/10.1111/jce.70375

Vancouver

van der Graaf M, Abeln BGS, Balt JC, Mittal S, Knight BP, Gunawardene MA, et al. Comparison of Two Pulsed Field Ablation Systems for Atrial Fibrillation: One‐Year Outcomes From a Multicenter Registry. Journal of Cardiovascular Electrophysiology. 2026;37(7):1522-1532. doi:10.1111/jce.70375

BibTeX
@article{vanderGraaf2026,
  author = {van der Graaf, Marisa and Abeln, Bob G S and Balt, Jippe C and Mittal, Suneet and Knight, Bradley P and Gunawardene, Melanie A and Wilsmore, Bradley and Amardeep, Amardeep and Harloff, Tim and Liebregts, Max and Malaty, Michael M and Musat, Dan L and Peigh, Graham and Singh, Supreet and Wijffels, Maurits C E F and Willems, Stephan and Verma, Nishant and van Dijk, Vincent F and Boersma, Lucas V A},
  title = {Comparison of Two Pulsed Field Ablation Systems for Atrial Fibrillation: One‐Year Outcomes From a Multicenter Registry},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {7},
  pages = {1522--1532},
  doi = {10.1111/jce.70375}
}
Start for free →