Safety and effectiveness of additional left atrial posterior wall ablation using pulsed field ablation for persistent and long‐standing persistent atrial fibrillation patients
Journal of Cardiovascular Electrophysiology · 2024
DOI: 10.1111/jce.16326 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Lucija Lisica Kordić und 6 weiteren Autor:innen. Beteiligte Einrichtung: Split Clinical Hospital Centre, Split, Croatia. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long‐term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter.
Methods
Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long‐term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24‐h Holter ECGs at 3, 6, and 12 months postablation; and 12‐lead ECGs recorded during symptomatic episodes or visits.
Results
Half of the patients had ls‐PerAF, and half had a history of catheter ablation—mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low‐voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow‐up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months.
Conclusion
PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Split Clinical Hospital Centre, Split, Croatia.
ORCID-Profile: Lucija Lisica Kordić, Zrinka Jurišić, Toni Brešković, Ivan Sikirić, Josip Katić, Ante Anić
Zitieren
APA
Kordić, L. L., Jurišić, Z., Brešković, T., Sikirić, I., Katić, J., Dagelic, M., & Anić, A. (2024). Safety and effectiveness of additional left atrial posterior wall ablation using pulsed field ablation for persistent and long‐standing persistent atrial fibrillation patients. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16326
Vancouver
Kordić LL, Jurišić Z, Brešković T, Sikirić I, Katić J, Dagelic M, et al. Safety and effectiveness of additional left atrial posterior wall ablation using pulsed field ablation for persistent and long‐standing persistent atrial fibrillation patients. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16326
BibTeX
@article{Kordi2024,
author = {Kordić, Lucija Lisica and Jurišić, Zrinka and Brešković, Toni and Sikirić, Ivan and Katić, Josip and Dagelic, Marija and Anić, Ante},
title = {Safety and effectiveness of additional left atrial posterior wall ablation using pulsed field ablation for persistent and long‐standing persistent atrial fibrillation patients},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16326}
}
EUVIMED