EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Long‐Term Outcomes of Leadless Pacemaker vs. Transvenous Pacemaker in End‐Stage Renal Disease

Siddharth Agarwal, Harsh P Patel, Shivaraj Patil, Anshul Gupta iD, Divya Patel, Zain Ul Abideen Asad, Muhammad Bilal Munir iD, Alan Sugrue, Nicholas Y Tan iD, Freddy Del-Carpio Munoz, Yong-Mei Cha, Christopher V DeSimone iD und 1 weitere

Journal of Cardiovascular Electrophysiology · 2026-07 · 37 (7) · 1599-1604

DOI: 10.1111/jce.70364 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 26.05.2026. Verfasst von Siddharth Agarwal und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Kidney Failure, Chronic, Pacemaker, Artificial, Renal Dialysis, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Patients with end‐stage renal disease (ESRD) undergoing dialysis have an increased risk of pacemaker‐related complications due to limited vascular access and increased susceptibility to infection. Leadless pacemakers (LPMs) may mitigate these risks compared with conventional transvenous pacemakers (TPMs), but long‐term comparative data in this population remain limited.

Methods

We conducted a retrospective cohort study using the TriNetX Research Network, including adults (≥ 18 years) with ESRD on dialysis who underwent LPM or TPM implantation between May 2016 and December 2020. Propensity score matching (1:1) was performed using demographics and comorbidities. Outcomes assessed over up to 5 years included all‐cause hospitalization, heart failure hospitalization, device re‐intervention, device‐related complications, infection‐related hospitalization, pacemaker‐induced cardiomyopathy, and all‐cause mortality.

Results

After matching, 901 patients were included in each group with well‐balanced baseline characteristics. LPM implantation was associated with a significantly lower risk of device re‐intervention compared with TPM (4.1% vs. 9.3%; hazard ratio [HR] 0.44; 95% confidence interval [CI] 0.28–0.69; p < 0.01). There were no significant differences between groups in all‐cause hospitalization (65.5% vs. 68.3%; p = 0.22), heart failure hospitalization (26.9% vs. 30.2%; p = 0.13), all‐cause mortality (37.5% vs. 35.3%; p = 0.34), device‐related complications (14.5% vs. 14.3%; p = 0.94), infection‐related hospitalization (1.6% vs. 2.1%; p = 0.35), or pacemaker‐induced cardiomyopathy (9.0% vs. 8.6%; p = 0.66).

Conclusion

In a large, propensity‐matched cohort of patients with ESRD on dialysis, LPMs were associated with fewer device re‐interventions and comparable long‐term clinical outcomes compared with TPMs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Kidney Failure, ChronicPacemaker, ArtificialRenal DialysisCardiac Pacing, ArtificialArrhythmias, CardiacHumansFemaleRetrospective StudiesTreatment OutcomeMaleTime FactorsAgedRisk FactorsMiddle AgedRisk AssessmentProsthesis DesignAged, 80 and over

Stichwörter der Autor:innen

end‐stage renal diseaseleadless pacemakermortalityoutcomestransvenous pacemaker

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Medicine, Allegheny General Hospital, Pittsburgh, Pennsylvania, USA.
  • Department of Medicine, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
  • Division of Cardiovascular Medicine, University of California Davis, Sacramento, California, USA.

ORCID-Profile: Anshul Gupta, Muhammad Bilal Munir, Nicholas Y Tan, Christopher V DeSimone

Zitieren

APA

Agarwal, S., Patel, H. P., Patil, S., Gupta, A., Patel, D., Asad, Z. U. A., Munir, M. B., Sugrue, A., Tan, N. Y., Munoz, F. D., Cha, Y. M., DeSimone, C. V., & Deshmukh, A. (2026). Long‐Term Outcomes of Leadless Pacemaker vs. Transvenous Pacemaker in End‐Stage Renal Disease. Journal of Cardiovascular Electrophysiology, 37(7), 1599-1604. https://doi.org/10.1111/jce.70364

Vancouver

Agarwal S, Patel HP, Patil S, Gupta A, Patel D, Asad ZUA, et al. Long‐Term Outcomes of Leadless Pacemaker vs. Transvenous Pacemaker in End‐Stage Renal Disease. Journal of Cardiovascular Electrophysiology. 2026;37(7):1599-1604. doi:10.1111/jce.70364

BibTeX
@article{Agarwal2026,
  author = {Agarwal, Siddharth and Patel, Harsh P and Patil, Shivaraj and Gupta, Anshul and Patel, Divya and Asad, Zain Ul Abideen and Munir, Muhammad Bilal and Sugrue, Alan and Tan, Nicholas Y and Munoz, Freddy Del-Carpio and Cha, Yong-Mei and DeSimone, Christopher V and Deshmukh, Abhishek},
  title = {Long‐Term Outcomes of Leadless Pacemaker vs. Transvenous Pacemaker in End‐Stage Renal Disease},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {7},
  pages = {1599--1604},
  doi = {10.1111/jce.70364}
}
Kostenlos starten →