EUVIMEDObjevte EUVIMED
Open access · CC BY-NC-ND 4.0

Dominant Frequency Mapping as a Functional Tool for Substrate‐Guided Ventricular Tachycardia Ablation

Selim M Zor iD, Wiert Hoeksema, Bart Baselmans, Michiel J B Kemme, Pieter G Postema, Pranav Bhagirath

Journal of Cardiovascular Electrophysiology · 2026-07 · 37 (7) · 1399-1409

DOI: 10.1111/jce.70356 ↗

At a glance

Journal article in Journal of Cardiovascular Electrophysiology, published online on 2026-05-03. Written by Selim M Zor and 5 co-authors. Institution: Department of Cardiology, Amsterdam University Medical Center, Amsterdam, the Netherlands. Major MEDLINE topics: Tachycardia, Ventricular, Catheter Ablation, Action Potentials, Electrophysiologic Techniques, Cardiac. 21 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: EHRA, Academy Van Leersum, Netherlands Heart Institute Fellowship.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Introduction

Accurate identification of arrhythmogenic substrate is essential for successful ventricular tachycardia (VT) ablation, yet existing electrogram‐based methods are limited by far‐field interference and operator dependence. Dominant frequency (DF) mapping offers a stimulus‐independent alternative, but existing implementations lack anatomically integrated workflows with quantitative assessment of spatial concordance.

Methods

The objective of this study is to develop and evaluate a computational workflow for DF mapping with three‐dimensional anatomical integration in patients undergoing substrate‐guided VT ablation. We retrospectively analyzed 12 patients (mean age 57.5 ± 18.0 years; 75% male) with ischemic or non‐ischemic cardiomyopathy. Intracardiac electrograms from SmartTouch or Pentaray catheters were segmented, transformed into the frequency domain, and thresholded using case‐specific histograms. DF activity was projected onto patient‐specific ventricular meshes, and spatial correspondence with operator‐defined ablation sites was quantified using continuous proximity metrics (soft recall, soft precision) and receiver operating characteristic (ROC) analysis.

Results

DF analysis was successful in all cases, with projection errors < 4 mm. DF activity showed high soft recall (0.776–0.999) and variable soft precision (0.025–0.754). ROC AUC values ranged from 0.622 to 0.953, exceeding baseline in all cases. SmartTouch data generally yielded higher recall and greater separation between ablation and non‐ablation points.

Conclusion

DF mapping with anatomical integration is feasible across catheter types and demonstrates consistent spatial concordance with operator‐defined VT ablation targets. This stimulus‐independent workflow can be applied to routine mapping data and provides a framework for quantitative assessment of spatial relationships with procedural targets. DF values were case‐specific and not comparable across patients, catheter types, or institutions. Prospective evaluation in larger cohorts is warranted.

Subjects

MeSH terms (MEDLINE)

Tachycardia, VentricularCatheter AblationAction PotentialsElectrophysiologic Techniques, CardiacHeart RateHumansMiddle AgedPredictive Value of TestsRetrospective StudiesMaleAgedFemaleTreatment OutcomeAdultWorkflowReproducibility of ResultsSignal Processing, Computer-Assisted

Author keywords

catheter ablationdominant frequencyfunctional substrate mappingpeak frequencyventricular tachycardia

Authors and institutions

  • Department of Cardiology, Amsterdam University Medical Center, Amsterdam, the Netherlands.
  • Biomedical Engineering, Amsterdam University of Applied Sciences, Amsterdam, the Netherlands.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

ORCID profiles: Selim M Zor

Funding

  • EHRA
  • Academy Van Leersum
  • Netherlands Heart Institute Fellowship
  • NIHR Biomedical Research Centre
  • NHS Foundation
  • King's College London
  • Dutch Heart Foundation
  • Hartstichting

Cite

APA

Zor, S. M., Hoeksema, W., Baselmans, B., Kemme, M. J. B., Postema, P. G., & Bhagirath, P. (2026). Dominant Frequency Mapping as a Functional Tool for Substrate‐Guided Ventricular Tachycardia Ablation. Journal of Cardiovascular Electrophysiology, 37(7), 1399-1409. https://doi.org/10.1111/jce.70356

Vancouver

Zor SM, Hoeksema W, Baselmans B, Kemme MJB, Postema PG, Bhagirath P. Dominant Frequency Mapping as a Functional Tool for Substrate‐Guided Ventricular Tachycardia Ablation. Journal of Cardiovascular Electrophysiology. 2026;37(7):1399-1409. doi:10.1111/jce.70356

BibTeX
@article{Zor2026,
  author = {Zor, Selim M and Hoeksema, Wiert and Baselmans, Bart and Kemme, Michiel J B and Postema, Pieter G and Bhagirath, Pranav},
  title = {Dominant Frequency Mapping as a Functional Tool for Substrate‐Guided Ventricular Tachycardia Ablation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {7},
  pages = {1399--1409},
  doi = {10.1111/jce.70356}
}