EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Near-field detection and peak frequency metric for substrate and activation mapping of ventricular tachycardias in two- and three-dimensional circuits

Johanna B Tonko iD, Cristina Lozano iD, Javier Moreno iD, Anthony Chow iD, Mehul Dhinoja iD, Pier D Lambiase iD

Europace · 02.07.2024 · 26 (7)

DOI: 10.1093/europace/euae154 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, online erschienen am 04.06.2024. Verfasst von Johanna B Tonko und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Cardiovascular Science, University College London, 5 University Street, London, WC1E 6JF, UK. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Catheter Ablation, Electrophysiologic Techniques, Cardiac, Algorithms. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Successful ventricular arrhythmia (VA) ablation requires identification of functionally critical sites during contact mapping. Estimation of the peak frequency (PF) component of the electrogram (EGM) may improve correct near-field (NF) annotation to identify circuit segments on the mapped surface. In turn, assessment of NF and far-field (FF) EGMs may delineate the three-dimensional path of a ventricular tachycardia (VT) circuit. Methods and results A proprietary NF detection algorithm was applied retrospectively to scar-related re-entry VT maps and compared with manually reviewed maps employing first deflection (FDcorr) for VT activation maps and last deflection (LD) for substrate maps. Ventricular tachycardia isthmus location and characteristics mapped with FDcorr vs. NF were compared. Omnipolar low-voltage areas, late activating areas, and deceleration zones (DZ) in LD vs. NF substrate maps were compared. On substrate maps, PF estimation was compared between isthmus and bystander sites. Activation mapping with entrainment and/or VT termination with radiofrequency (RF) ablation confirmed critical sites. Eighteen patients with high-density VT activation and substrate maps (55.6% ischaemic) were included. Near-field detection correctly located critical parts of the circuit in 77.7% of the cases compared with manually reviewed VT maps as reference. In substrate maps, NF detection identified deceleration zones in 88.8% of cases, which overlapped with FDcorr VT isthmus in 72.2% compared with 83.3% overlap of DZ assessed by LD. Applied to substrate maps, PF as a stand-alone feature did not differentiate VT isthmus sites from low-voltage bystander sites. Omnipolar voltage was significantly higher at isthmus sites with longer EGM durations compared with low-voltage bystander sites.

Conclusion

The NF algorithm may enable rapid high-density activation mapping of VT circuits in the NF of the mapped surface. Integrated assessment and combined analysis of NF and FF EGM-components could support characterization of three-dimensional VT circuits with intramural segments. For scar-related substrate mapping, PF as a stand-alone EGM feature did not enable the differentiation of functionally critical sites of the dominant VT from low-voltage bystander sites in this cohort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tachycardia, VentricularCatheter AblationElectrophysiologic Techniques, CardiacAlgorithmsHumansFemaleMaleRetrospective StudiesMiddle AgedAction PotentialsAgedHeart RatePredictive Value of TestsSignal Processing, Computer-Assisted

Stichwörter der Autor:innen

Activation mappingCatheter ablationFrequency domainLocal activation timeNear-field detectionPeak frequencySubstrate mappingVentricular tachycardia

Autor:innen und Institutionen

  • Institute for Cardiovascular Science, University College London, 5 University Street, London, WC1E 6JF, UK.
  • Barts Heart Centre, St Bartholomew s Hospital, W Smithfield, London EC1A 7BE, UK.
  • Department of Cardiology, Hospital Universitario Ramón Y Cajal, Colmenar Viejo road, km. 9,100, Madrid 28034, Spain.

ORCID-Profile: Johanna B Tonko, Cristina Lozano, Javier Moreno, Anthony Chow, Mehul Dhinoja, Pier D Lambiase

Zitieren

APA

Tonko, J. B., Lozano, C., Moreno, J., Chow, A., Dhinoja, M., & Lambiase, P. D. (2024). Near-field detection and peak frequency metric for substrate and activation mapping of ventricular tachycardias in two- and three-dimensional circuits. Europace, 26(7). https://doi.org/10.1093/europace/euae154

Vancouver

Tonko JB, Lozano C, Moreno J, Chow A, Dhinoja M, Lambiase PD. Near-field detection and peak frequency metric for substrate and activation mapping of ventricular tachycardias in two- and three-dimensional circuits. Europace. 2024;26(7). doi:10.1093/europace/euae154

BibTeX
@article{Tonko2024,
  author = {Tonko, Johanna B and Lozano, Cristina and Moreno, Javier and Chow, Anthony and Dhinoja, Mehul and Lambiase, Pier D},
  title = {Near-field detection and peak frequency metric for substrate and activation mapping of ventricular tachycardias in two- and three-dimensional circuits},
  journal = {Europace},
  year = {2024},
  volume = {26},
  number = {7},
  doi = {10.1093/europace/euae154}
}
Kostenlos starten →