EUVIMEDOpdag EUVIMED
Fallbericht

Novel Use of Helium Insufflation to Facilitate Epicardial Access in Ventricular Tachycardia Ablation

Engin Algül, Yunus Öz iD, Haluk Furkan Şahan, Sinan İşcen, Tolga Han Efe, Hamza Sunman, Özcan Özdemir

Journal of Cardiovascular Electrophysiology · 2026-06 · 37 (6) · 1359-1362

DOI: 10.1111/jce.70313 ↗

At a glance

Fallbericht in Journal of Cardiovascular Electrophysiology, published online on 2026-03-09. Written by Engin Algül and 6 co-authors. Institution: Department of Cardiology, University of Health Sciences, Ankara Etlik City Hospital, Ankara, Turkey. Major MEDLINE topics: Tachycardia, Ventricular, Catheter Ablation, Insufflation, Pericardium. 9 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Epicardial access for ventricular tachycardia (VT) ablation is challenging in patients with prior cardiac surgery or dense pericardial adhesions. Although carbon dioxide (CO₂) insufflation has been used to improve visualization, concerns remain regarding its hemodynamic and electrophysiological effects. Methods and Results We report the first clinical use of helium to facilitate epicardial access in three patients undergoing VT ablation. All patients had ischemic cardiomyopathy, prior coronary artery bypass grafting, and failed or incomplete endocardial ablation. Helium was delivered into the pericardial space via a coronary venous microcatheter connected to an intra‐aortic balloon pump (IABP) console, allowing controlled insufflation and continuous hemodynamic monitoring. Helium insufflation resulted in rapid separation of the pericardial layers, clear visualization of adhesion‐free regions, and safe epicardial puncture in all cases. Epicardial mapping and radiofrequency ablation were successfully completed, achieving VT non‐inducibility without hemodynamic compromise, defibrillation related issues or procedural complications.

Conclusion

Helium insufflation using an IABP console enabled safe and effective epicardial access in patients with complex pericardial anatomy and prior cardiac surgery. As a physiologically inert, low‐viscosity, and widely available gas, helium represents a practical alternative to CO₂ for challenging epicardial VT ablation procedures and merits further evaluation in larger studies.

Subjects

MeSH terms (MEDLINE)

Tachycardia, VentricularCatheter AblationInsufflationPericardiumHeliumHumansTreatment OutcomeMaleAgedMiddle AgedFemale

Author keywords

electrophysiologyepicardial accesspericardial adhesionsventricular tachycardia ablation

Substances

Helium

Authors and institutions

  • Department of Cardiology, University of Health Sciences, Ankara Etlik City Hospital, Ankara, Turkey.

ORCID profiles: Yunus Öz

Cite

APA

Algül, E., Öz, Y., Şahan, H. F., İşcen, S., Efe, T. H., Sunman, H., & Özdemir, Ö. (2026). Novel Use of Helium Insufflation to Facilitate Epicardial Access in Ventricular Tachycardia Ablation. Journal of Cardiovascular Electrophysiology, 37(6), 1359-1362. https://doi.org/10.1111/jce.70313

Vancouver

Algül E, Öz Y, Şahan HF, İşcen S, Efe TH, Sunman H, et al. Novel Use of Helium Insufflation to Facilitate Epicardial Access in Ventricular Tachycardia Ablation. Journal of Cardiovascular Electrophysiology. 2026;37(6):1359-1362. doi:10.1111/jce.70313

BibTeX
@article{Algl2026,
  author = {Algül, Engin and Öz, Yunus and Şahan, Haluk Furkan and İşcen, Sinan and Efe, Tolga Han and Sunman, Hamza and Özdemir, Özcan},
  title = {Novel Use of Helium Insufflation to Facilitate Epicardial Access in Ventricular Tachycardia Ablation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {6},
  pages = {1359--1362},
  doi = {10.1111/jce.70313}
}
Start for free →