Safety of Carbon Dioxide–Facilitated vs Conventional Epicardial Access
JACC: Clinical Electrophysiology · 2026
DOI: 10.1016/j.jacep.2026.01.001 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift JACC: Clinical Electrophysiology, 2026. Verfasst von Beatriz Castello-Branco und 13 weiteren Autor:innen. Beteiligte Einrichtung: Electrophysiology Section, Advanced Arrhythmia Treatment Center, Belo Horizonte, Brazil. Hauptthemen laut MEDLINE: Carbon Dioxide, Pericardium, Catheter Ablation, Tachycardia, Ventricular. Die Arbeit nennt 31 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Percutaneous epicardial access has been increasingly adopted in clinical practice, particularly for ventricular tachycardia ablation. "Dry" epicardial puncture (Dry-EPI) carries a considerable risk of access-related complications, even with modified techniques. Pericardial carbon dioxide insufflation (EpiCO2) has emerged as a promising alternative, potentially enhancing safety by increasing anatomical clearance between pericardial layers. OBJECTIVES: This study compared the safety and efficacy of EpiCO2 vs traditional Dry-EPI techniques through systematic review, meta-analysis, and meta-regression. METHODS: PubMed/MEDLINE, Embase, Scopus, Web of Science, and Cochrane databases were searched using medical subject heading terms "epicardial access," "carbon dioxide insufflation," "complications," and similar key words. Random-effects meta-analyses of proportions and means, subgroup analyses, and meta-regressions were conducted. RESULTS: A total of 119 studies (8,784 procedures) were included; most (95.0%) were of moderate or high quality. Ventricular tachycardia ablation was the main access indication (n = 7,178). EpiCO2 was used in 493 procedures (5.6%) and Dry-EPI in 8,291 (94.4%). Among 5,786 Dry-EPI cases with specified needle type, 5,184 (89.6%) used a large-bore needle and 602 (10.4%) a micropuncture needle. EpiCO2 was associated with significantly fewer complications requiring surgery compared with Dry-EPI (0.24% [95% CI: 0.00-0.93] vs 1.55% [95% CI: 1.27-1.86], P < 0.010), large-bore needle (0.24% [95% CI: 0.00%-0.93%] vs 1.58% [95% CI: 1.23-1.97], P < 0.010), and micropuncture (0.24 [95% CI: 0.00-0.93] vs 1.66% [95% CI: 0.60-3.17], P = 0.020). Inadvertent ventricular puncture was also lower with EpiCO2 compared with Dry-EPI (0.28% [95% CI: 0.00-1.00] vs 3.17% [95% CI: 2.36-4.10], P < 0.010). CONCLUSIONS: Compared with Dry-EPI, EpiCO2 was associated with significantly lower risk of inadvertent ventricular puncture and complications requiring surgery, supporting broader clinical adoption.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Electrophysiology Section, Advanced Arrhythmia Treatment Center, Belo Horizonte, Brazil.
- Section of Cardiac Pacing and Electrophysiology, Division of Cardiology, Cleveland Clinic, Cleveland, Ohio, USA.
- Electrophysiology Section, Advanced Arrhythmia Treatment Center, Belo Horizonte, Brazil; Unit of Cardiology and Cardiovascular Surgery, Clinics Hospital, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
- Section of Cardiac Pacing and Electrophysiology, Division of Cardiology, Cleveland Clinic, Cleveland, Ohio, USA. Electronic address: santanp3@ccf.org.
Zitieren
APA
Castello-Branco, B., Wilnes, B., Sroubek, J., Higuchi, K., Lee, J., Hussein, A., Saliba, W., Kanj, M., Taigen, T., Younis, A., Bhargava, M., Wazni, O., Carmo, A. A. L., & Santangeli, P. (2026). Safety of Carbon Dioxide–Facilitated vs Conventional Epicardial Access. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2026.01.001
Vancouver
Castello-Branco B, Wilnes B, Sroubek J, Higuchi K, Lee J, Hussein A, et al. Safety of Carbon Dioxide–Facilitated vs Conventional Epicardial Access. JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2026.01.001
BibTeX
@article{CastelloBranco2026,
author = {Castello-Branco, Beatriz and Wilnes, Bruno and Sroubek, Jakub and Higuchi, Koji and Lee, Justin and Hussein, Ayman and Saliba, Walid and Kanj, Mohamed and Taigen, Tyler and Younis, Arwa and Bhargava, Mandeep and Wazni, Oussama and Carmo, André A L and Santangeli, Pasquale},
title = {Safety of Carbon Dioxide–Facilitated vs Conventional Epicardial Access},
journal = {JACC: Clinical Electrophysiology},
year = {2026},
doi = {10.1016/j.jacep.2026.01.001}
}
EUVIMED