EUVIMEDOpdag EUVIMED
Klinische StudieOpen access · CC BY-NC 4.0

Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study

Cheyenne S L Chiu iD, Akke van Dijkhuizen, Willem Gerrits, Maarten J Cramer, Anton E Tuinenburg iD, Pim van der Harst iD, Mathias Meine iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.70060 ↗

At a glance

Klinische Studie in Journal of Cardiovascular Electrophysiology, 2025. Written by Cheyenne S L Chiu and 6 co-authors. Institution: Department of Cardiology, Division Heart & Lungs, University Medical Center Utrecht, Utrecht, the Netherlands. Major MEDLINE topics: Defibrillators, Implantable, Electric Countershock, Tachycardia, Ventricular, Unnecessary Procedures. Cited 2 times so far (Crossref); 20 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: This study was supported by Medtronic., Medtronic.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Advances in implantable cardioverter‐defibrillator (ICD) programming strategies have achieved significant reductions in inappropriate shocks. However, further refinement is needed to minimize appropriate but unnecessary therapies. The ENHANCED‐ICD study initially demonstrated the short‐term safety and efficacy of programming a number of intervals to detect (NID) of 60/80 over a median follow‐up of 1.3 years. A decade later, this study presents the long‐term impacts of this programming strategy.

Objective

To assess the long‐term impact of programming NID 60/80 for ventricular tachycardia (VT)/ventricular fibrillation (VF) detection on adverse events related to shocks and arrhythmias, as well as on ICD therapies—both delivered and avoided.

Methods

A retrospective analysis was conducted on 60 patients from the ENHANCED‐ICD study, a prospective, single‐center trial. The median age was 60 years, 78% were men, and 53% had a primary prevention ICD indication. A prolonged detection interval of NID 60/80 was programmed for VT/VF detection. The cycle lengths for VT/fast VT/VF were set at 360/330/240 ms, respectively.

Results

After a median follow‐up of 9.4 years, Enhanced programming prevented unnecessary ICD therapies in 16.7% of patients and reduced the overall therapy rate by 25.9%. A total of 26.7% of patients received ICD therapy, with appropriate therapy delivered in 23.3% and inappropriate therapy occurring in 3.3% of patients. No arrhythmic deaths were observed, while syncope was reported in 10.0% of patients (1.63 per 100 patient‐years).

Conclusion

Prolonging the ICD detection interval to an NID of 60/80 successfully prevented appropriate but unnecessary therapy, while maintaining safety during long‐term follow‐up. Trial Registration: The ENHANCED‐ICD study registered on http://ClinicalTrials.gov under study ID NCT01715116.

Subjects

MeSH terms (MEDLINE)

Defibrillators, ImplantableElectric CountershockTachycardia, VentricularUnnecessary ProceduresVentricular FibrillationAgedFemaleHumansMaleMiddle AgedAction PotentialsRetrospective StudiesRisk FactorsTime FactorsTreatment Outcome

Author keywords

ICD therapyantitachycardia pacingdetectionimplantable cardioverter‐defibrillatorshockventricular arrhythmias

Authors and institutions

  • Department of Cardiology, Division Heart & Lungs, University Medical Center Utrecht, Utrecht, the Netherlands.

ORCID profiles: Cheyenne S L Chiu, Anton E Tuinenburg, Pim van der Harst, Mathias Meine

Funding

  • This study was supported by Medtronic.
  • Medtronic

Cite

APA

Chiu, C. S. L., van Dijkhuizen, A., Gerrits, W., Cramer, M. J., Tuinenburg, A. E., van der Harst, P., & Meine, M. (2025). Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70060

Vancouver

Chiu CSL, van Dijkhuizen A, Gerrits W, Cramer MJ, Tuinenburg AE, van der Harst P, et al. Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.70060

BibTeX
@article{Chiu2025,
  author = {Chiu, Cheyenne S L and van Dijkhuizen, Akke and Gerrits, Willem and Cramer, Maarten J and Tuinenburg, Anton E and van der Harst, Pim and Meine, Mathias},
  title = {Reducing Unnecessary Implantable Cardioverter‐Defibrillator Therapy With ENHANCED Programming: Long‐Term Outcomes of the ENHANCED‐ICD Study},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.70060}
}
Start for free →