EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

The Extent of Pulmonary Vein Electrical Connections Predicts the Success of Stand‐Alone Pulmonary Vein Isolation in Persistent Atrial Fibrillation

Matteo Marchetti iD, Christelle Haddad iD, Adrian Luca iD, Mathieu Le Bloa, Cheryl Teres, Giulia Domenichini iD, Alessandra Pia Porretta, Claudia Herrera, Etienne Pruvot, Patrizio Pascale iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16622 ↗

At a glance

Journal article in Journal of Cardiovascular Electrophysiology, 2025. Written by Matteo Marchetti and 9 co-authors. Institution: Arrhythmia Unit, Cardiovascular Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland. Major MEDLINE topics: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation, Action Potentials. Cited 2 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY 4.0). Funded by: This work was supported by the Schweizerischer National fonds zur Förderung der Wissenschaftlichen Forschung..

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Identification of persistent AF (PsAF) patients who may be cured with stand‐alone pulmonary vein isolation (PVI) would allow more efficient ablation strategies. Intuitively, the benefit of PVI is expected to be lower when PVs are poorly connected, but this assumption has never been tested.

Objective

Evaluate whether the circumferential extent of PV connections assessed pre‐ablation predicts the success rate of PVI.

Methods

Consecutive patients with PsAF undergoing first ablation with stand‐alone PVI were included. The extent of PV electrical connection was assessed using a circular mapping catheter and graded as limited, moderate, or extensive, according to tertiles of the mean numbers of bipoles recording PV potentials along the circumference of each vein.

Results

One hundred and forty‐eight patients were included (age 64 ± 9.7 years, PsAF duration 7.3 ± 7 months). After a mean follow‐up of 38.6 ± 7.8 months, freedom from arrhythmia recurrence after last PVI was significantly lower in patients with limited (38.6%), compared to moderate, and extensive PV connections (69.7% and 69%, respectively; p = 0.002). While redo PVI procedures did not significantly affect final ablation outcomes in patients with limited PV connections, a significant incremental arrhythmia‐free survival gain was observed with increasing extent of PV connections ( p < 0.01).

Conclusions

The circumferential extent of PV connections is correlated to the success rate of PVI in patients with PsAF and may be a marker of the contribution of PVs to AF. The finding of limited PV connections may be used to select patients who may benefit from first‐line adjunctive ablation.

Subjects

MeSH terms (MEDLINE)

Pulmonary VeinsAtrial FibrillationCatheter AblationAction PotentialsHumansMaleMiddle AgedFemaleAgedRecurrenceTime FactorsElectrophysiologic Techniques, CardiacTreatment OutcomeHeart RateRetrospective StudiesProgression-Free SurvivalRisk FactorsPredictive Value of Tests

Author keywords

catheter ablationpersistent atrial fibrillationpulmonary vein activitypulmonary vein connectionpulmonary vein isolation

Authors and institutions

  • Arrhythmia Unit, Cardiovascular Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland.
  • Arrhythmia Unit, Louis Pradel Cardiovascular Hospital, Hospices Civils de Lyon, Lyon, France.
  • Arrhythmia Unit, Hôpital Bichat Claude-Bernard, Assistance Publique Hôpitaux de Paris, Paris, France.

ORCID profiles: Matteo Marchetti, Christelle Haddad, Adrian Luca, Giulia Domenichini, Patrizio Pascale

Funding

  • This work was supported by the Schweizerischer National fonds zur Förderung der Wissenschaftlichen Forschung.

Cite

APA

Marchetti, M., Haddad, C., Luca, A., Le Bloa, M., Teres, C., Domenichini, G., Porretta, A. P., Herrera, C., Pruvot, E., & Pascale, P. (2025). The Extent of Pulmonary Vein Electrical Connections Predicts the Success of Stand‐Alone Pulmonary Vein Isolation in Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16622

Vancouver

Marchetti M, Haddad C, Luca A, Le Bloa M, Teres C, Domenichini G, et al. The Extent of Pulmonary Vein Electrical Connections Predicts the Success of Stand‐Alone Pulmonary Vein Isolation in Persistent Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16622

BibTeX
@article{Marchetti2025,
  author = {Marchetti, Matteo and Haddad, Christelle and Luca, Adrian and Le Bloa, Mathieu and Teres, Cheryl and Domenichini, Giulia and Porretta, Alessandra Pia and Herrera, Claudia and Pruvot, Etienne and Pascale, Patrizio},
  title = {The Extent of Pulmonary Vein Electrical Connections Predicts the Success of Stand‐Alone Pulmonary Vein Isolation in Persistent Atrial Fibrillation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16622}
}
Start for free →