The Neglected Parameter: Tricuspidal E Wave Deceleration Time as Predictor of Atrioventricular Synchrony in VDD Leadless Pacemakers

Mattia Strazzanti, Caterina Maffeis, Luca Tomasi, Sofia Capocci, Bruna Bolzan, Elena Franchi, Flavio Luciano Ribichini, Giacomo Mugnai iD

Journal of Cardiovascular Electrophysiology · 2025-05 · 36 (5) · 1064-1067

DOI: 10.1111/jce.16613 ↗

At a glance

Journal article in Journal of Cardiovascular Electrophysiology, published online on 2025-03-10. Written by Mattia Strazzanti and 7 co-authors. Institution: Cardiology Division, Department of Cardiac, Thoracic and Vascular Sciences, Carlo Poma Hospital, Mantua, Italy. Major MEDLINE topics: Pacemaker, Artificial, Cardiac Pacing, Artificial, Heart Rate, Atrial Function, Right. Cited 1 times so far (Crossref); 6 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Leadless pacemakers as the Medtronic Micra AV, have improved cardiac pacing by reducing complications associated with traditional systems. However, achieving high atrioventricular synchrony (AVS) remains a challenge, especially in patients with a high pacing burden. This prospective study enrolled 30 patients to assess the role of echocardiographic parameters in predicting AVS postimplantation. AVS was evaluated via 24‐h Holter monitoring, with a median AVS of 67.9% ± 9.6%. Right atrial function, particularly the tricuspidal E wave deceleration time, emerged as the only independent predictor of AVS ( p = 0.03), with an AUC of 0.77. These findings suggest that pre‐implantation echocardiographic assessment of right atrial parameters could aid in selecting patients who would benefit most from Micra AV. Further studies with larger cohorts and extended follow‐ups are warranted.

Subjects

MeSH terms (MEDLINE)

Pacemaker, ArtificialCardiac Pacing, ArtificialHeart RateAtrial Function, RightArrhythmias, CardiacAtrioventricular NodeHumansFemaleProspective StudiesMaleAgedPredictive Value of TestsTime FactorsElectrocardiography, AmbulatoryMiddle AgedAction PotentialsTreatment OutcomeEquipment DesignAged, 80 and over

Author keywords

clinical: implantable devices – pacemaker‐bradyarrhythmias

Authors and institutions

  • Cardiology Division, Department of Cardiac, Thoracic and Vascular Sciences, Carlo Poma Hospital, Mantua, Italy.
  • Cardiology Division, Department of Medicine, School of Medicine, University of Verona, Verona, Italy.

ORCID profiles: Giacomo Mugnai

Cite

APA

Strazzanti, M., Maffeis, C., Tomasi, L., Capocci, S., Bolzan, B., Franchi, E., Ribichini, F. L., & Mugnai, G. (2025). The Neglected Parameter: Tricuspidal E Wave Deceleration Time as Predictor of Atrioventricular Synchrony in VDD Leadless Pacemakers. Journal of Cardiovascular Electrophysiology, 36(5), 1064-1067. https://doi.org/10.1111/jce.16613

Vancouver

Strazzanti M, Maffeis C, Tomasi L, Capocci S, Bolzan B, Franchi E, et al. The Neglected Parameter: Tricuspidal E Wave Deceleration Time as Predictor of Atrioventricular Synchrony in VDD Leadless Pacemakers. Journal of Cardiovascular Electrophysiology. 2025;36(5):1064-1067. doi:10.1111/jce.16613

BibTeX
@article{Strazzanti2025,
  author = {Strazzanti, Mattia and Maffeis, Caterina and Tomasi, Luca and Capocci, Sofia and Bolzan, Bruna and Franchi, Elena and Ribichini, Flavio Luciano and Mugnai, Giacomo},
  title = {The Neglected Parameter: Tricuspidal E Wave Deceleration Time as Predictor of Atrioventricular Synchrony in VDD Leadless Pacemakers},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  volume = {36},
  number = {5},
  pages = {1064--1067},
  doi = {10.1111/jce.16613}
}
Start for free →