Editorial: Cardiac implantable electronic device‐induced tricuspid regurgitation: Implications and management
Journal of Cardiovascular Electrophysiology · 2024
DOI: 10.1111/jce.16271 ↗At a glance
Editorial in Journal of Cardiovascular Electrophysiology, 2024. Written by George H Crossley and 1 co-authors. Institution: Vanderbilt Heart and Vascular Institute, Vanderbilt University Medical Center, Nashville, Tennessee, USA. Major MEDLINE topics: Tricuspid Valve Insufficiency, Defibrillators, Implantable, Pacemaker, Artificial. 12 references.
Abstract (original language)
‐ away from the tricuspid valve, thus suggesting that ventricular desynchrony from pacing may play a role. Even more surprising was the report in a small, randomized study demonstrating that coronary sinus pacing did not cause less TR than traditional trans ‐ venous pacing. 8 There are also data regarding non ‐ apical lead placement. RVOT pacing has been suggested to cause less TR than RV apical pacing 9 with a few reports indicating that RV septal pacing may lead to more TR. 10 It is possible that CIED ‐ associated TR from RV septal pacing may be due to pinning the septal leaflet of the tricuspid valve. The authors strongly suggest a role for three ‐ dimensional transesophageal echocardiography (3DTEE) in patients with significant TR. While, in the past, the optimal imaging method for the assessment of TR was controversial, consensus has now formed around TEE and, more specifically, three ‐ dimensional TEE as the optimal method. 11 A similar role has been suggested for three ‐ dimensional intracardiac echocardiography, but robust data are not yet available. 12 In summary, the authors remind us that TR is a significant clinical problem and that it can be evaluated well by 3DTEE, but that the mechanisms of the development of thatTR remain unclear. While it is likely best to avoid entanglement between the lead and the tricuspid apparatus, just how to prevent or treat CIED ‐ related TR is uncertain.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Vanderbilt Heart and Vascular Institute, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
ORCID profiles: George H Crossley, Jamie Kowal
Cite
APA
Crossley, G. H., & Kowal, J. (2024). Editorial: Cardiac implantable electronic device‐induced tricuspid regurgitation: Implications and management. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16271
Vancouver
Crossley GH, Kowal J. Editorial: Cardiac implantable electronic device‐induced tricuspid regurgitation: Implications and management. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16271
BibTeX
@article{Crossley2024,
author = {Crossley, George H and Kowal, Jamie},
title = {Editorial: Cardiac implantable electronic device‐induced tricuspid regurgitation: Implications and management},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16271}
}
EUVIMED