EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction

Federico Migliore iD, Raimondo Pittorru iD, Manuel De Lazzari iD, Pietro Bernardo Dall'Aglio iD, Antonella Cecchetto iD, Marco Previtero iD, Valeria Pergola iD, Gaetano Thiene iD, Giulia Masiero iD, Giuseppe Tarantini iD, Vincenzo Tarzia, Gino Gerosa iD

Europace · 2024

DOI: 10.1093/europace/euae191 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, 2024. Verfasst von Federico Migliore und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy. Hauptthemen laut MEDLINE: Tricuspid Valve Insufficiency, Device Removal, Defibrillators, Implantable. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Transvenous lead extraction (TLE) is potentially complicated by significant tricuspid valve regurgitation increase (TRI). However, there are limited data on the effect of the bidirectional rotational mechanical sheaths on significant TRI. The aim of the present study was to investigate the rate of significant changes in tricuspid regurgitation (TR) severity following mechanical rotational TLE and their outcomes. Methods and results In 158 patients (mean age 66 ± 16.9 years) undergoing mechanical rotational TLE, acute changes in TR severity were assessed by echocardiography evaluation. A significant acute TRI was defined as an increase of at least one grade with a post-extraction severity at least moderate. A total of 290 leads were extracted (mean implant duration, 93 ± 65 months). Significant TRI was noted in 5.7% of patients, and it was linked to tricuspid valve damage, TLE infection indication, and longer lead implant duration. Univariate predictors of significant TRI included implant duration of all leads [odds ratio (OR) 1.01; 95% confidence interval (CI) 1.003–1.018; P = 0.001] and right ventricular leads (OR 1.01; 95% CI 1.004–1.017; P = 0.002). Severe increase of TR following TLE was an independent predictor of mortality [hazard ratio (HR) 5.20; 95% CI 1.44–18.73; P = 0.012 ] along with severe systolic dysfunction (HR 2.37; 95% CI 1.01–5.20; P = 0.032), and systemic infection (HR 2.28; 95% CI 1.06–4.89; P = 0.035).

Conclusion

Significant TRI was detected in 5.7% of patients following transvenous rotational mechanical lead extraction. The duration of lead implantation emerged as the sole predictor of significant TRI. Physicians engaged in TLE should exercise greater vigilance for this potential complication.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tricuspid Valve InsufficiencyDevice RemovalDefibrillators, ImplantableHumansMaleFemaleAgedMiddle AgedAged, 80 and overSeverity of Illness IndexRisk FactorsTreatment OutcomePacemaker, ArtificialRetrospective StudiesTricuspid ValveTime Factors

Stichwörter der Autor:innen

ComplicationsMechanical lead extractionTransvenous lead extractionTricuspid valve damageTricuspid valve regurgitation

Autor:innen und Institutionen

  • Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy.
  • Department of Cardiology and Medical Intensive Care, St. Josef Hospital Freiburg, Freiburg, Germany.

ORCID-Profile: Federico Migliore, Raimondo Pittorru, Manuel De Lazzari, Pietro Bernardo Dall'Aglio, Antonella Cecchetto, Marco Previtero, Valeria Pergola, Gaetano Thiene, Giulia Masiero, Giuseppe Tarantini, Gino Gerosa

Zitieren

APA

Migliore, F., Pittorru, R., De Lazzari, M., Dall'Aglio, P. B., Cecchetto, A., Previtero, M., Pergola, V., Thiene, G., Masiero, G., Tarantini, G., Tarzia, V., & Gerosa, G. (2024). Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction. Europace. https://doi.org/10.1093/europace/euae191

Vancouver

Migliore F, Pittorru R, De Lazzari M, Dall'Aglio PB, Cecchetto A, Previtero M, et al. Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction. Europace. 2024. doi:10.1093/europace/euae191

BibTeX
@article{Migliore2024,
  author = {Migliore, Federico and Pittorru, Raimondo and De Lazzari, Manuel and Dall'Aglio, Pietro Bernardo and Cecchetto, Antonella and Previtero, Marco and Pergola, Valeria and Thiene, Gaetano and Masiero, Giulia and Tarantini, Giuseppe and Tarzia, Vincenzo and Gerosa, Gino},
  title = {Evaluation of tricuspid valve regurgitation following transvenous rotational mechanical lead extraction},
  journal = {Europace},
  year = {2024},
  doi = {10.1093/europace/euae191}
}
Kostenlos starten →