EUVIMEDObjevte EUVIMED
EditorialKommentar

In silico experiments explain the non‐consistent benefit of conduction system pacing over cardiac resynchronization therapy. The need to personalize therapy

María S Guillem, Margarida Pujol-López iD, Jorge Sanchez-Arciniegas, Lluís Mont iD

Journal of Cardiovascular Electrophysiology · 2023

DOI: 10.1111/jce.15871 ↗

At a glance

Editorial in Journal of Cardiovascular Electrophysiology, 2023. Written by María S Guillem and 3 co-authors. Institution: ITACA Institute, Universitat Politècnica de València, Valencia, Spain. Major MEDLINE topics: Cardiac Resynchronization Therapy. Cited 3 times so far (Crossref); 15 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Conduction system pacing (CSP) has emerged as an alternative treatment for patients with indication for cardiac resynchronization therapy (CRT). As opposed to biventricular CRT (BIV-CRT), which is based on left epicardial stimulation, CSP aims to restore the conduction through the His-Purkinje system pacing distally to level of block. Randomized evidence with His bundle pacing (HBP)(1–3) and left bundle branch pacing (LBBP)(4,5) is not extensive compared with the available BIV-CRT data. Non-inferiority of CSP as compared to BIV-CRT has been proven in a randomized trial (LEVEL-AT)(4); furthermore, the LBBP-RESYNC trial(5) has shown greater left ventricular (LV) ejection fraction improvement with LBBP versus BiV-CRT in non-ischemic patients with left bundle branch block (LBBB).

Subjects

MeSH terms (MEDLINE)

Cardiac Resynchronization TherapyHumansHeart Conduction SystemCardiac Conduction System Disease

Author keywords

cardiac resynchronization therapyconduction system pacingelectrocardiographic imagingscar

Authors and institutions

  • ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
  • Secció d'Arrítmies, Institut Clínic Cardiovascular, Hospital Clínic de Barcelona, Barcelona, Catalonia, Spain.
  • Institut de Recerca Biomèdica August Pi i Sunyer (IDIBAPS), Barcelona, Catalonia, Spain.
  • Centro de Investigación Biomédica en Red Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain.

ORCID profiles: Margarida Pujol-López, Lluís Mont

Cite

APA

Guillem, M. S., Pujol-López, M., Sanchez-Arciniegas, J., & Mont, L. (2023). In silico experiments explain the non‐consistent benefit of conduction system pacing over cardiac resynchronization therapy. The need to personalize therapy. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.15871

Vancouver

Guillem MS, Pujol-López M, Sanchez-Arciniegas J, Mont L. In silico experiments explain the non‐consistent benefit of conduction system pacing over cardiac resynchronization therapy. The need to personalize therapy. Journal of Cardiovascular Electrophysiology. 2023. doi:10.1111/jce.15871

BibTeX
@article{Guillem2023,
  author = {Guillem, María S and Pujol-López, Margarida and Sanchez-Arciniegas, Jorge and Mont, Lluís},
  title = {In silico experiments explain the non‐consistent benefit of conduction system pacing over cardiac resynchronization therapy. The need to personalize therapy},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2023},
  doi = {10.1111/jce.15871}
}
Start for free →