Improving Visualization via Polytetrafluoroethylene Mesh in 3D Computed Tomography Imaging After Laparoscopic Sacrocolpopexy
International Journal of Urology · 2025
DOI: 10.1111/iju.70186 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift International Journal of Urology, 2025. Verfasst von Akane Yamaguchi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, University of Tsukuba Hospital, Tsukuba, Ibaraki, Japan. Hauptthemen laut MEDLINE: Surgical Mesh, Polytetrafluoroethylene, Imaging, Three-Dimensional, Tomography, X-Ray Computed. Die Arbeit nennt 12 Literaturangaben.
Abstract (Originalsprache)
Objectives
Non‐radiolucent polytetrafluoroethylene (PTFE) mesh is used in transvaginal mesh (TVM) surgery and laparoscopic sacrocolpopexy (LSC) in Japan. Although a previous study demonstrated PTFE mesh visualization using computed tomography (CT) after TVM, its visualization in LSC remains unclear. This study aimed to use CT to quantify PTFE mesh visualization after LSC and determine whether three‐dimensional (3D) mesh visualization could be achieved.
Methods
This retrospective multicenter study included 107 patients who underwent LSC at one of four institutions between June 2021 and November 2022, with CT imaging being performed over 6 weeks postoperatively. Three‐dimensional CT images were generated using SYNAPSE VINCENT software. Three assessors assessed visualization rates for three mesh parts (arm, anterior body, posterior body), with the anterior and posterior bodies being divided into four sections. Visualization was scored using a 5‐point scale (0: invisible to 4: 100% visible).
Results
The median visualization rates were 4.0 (3.7–4.0) for the arm, 3.3 (3.1–3.6) for the anterior body, and 2.5 (2.3–2.8) for the posterior body. Three‐dimensional images were successfully obtained in all cases. The anterior body showed significantly higher visualization rates on the distal side, while the posterior body exhibited no significant differences across sections.
Conclusions
CT demonstrated high visualization rates for PTFE mesh implanted during LSC, particularly for the arm and anterior body. Complete 3D CT visualization of the PTFE mesh was achieved in all cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Urology, University of Tsukuba Hospital, Tsukuba, Ibaraki, Japan.
- Department of Urology, Japanese Red Cross Gifu Hospital, Gifu, Japan.
- Department of Urology, Saiseikai Chuwa Hospital, Sakurai, Nara, Japan.
- Department of Urogynecology, Daiichi Towakai Hospital, Takatsuki, Osaka, Japan.
- Niimura Hospital, Kagoshima, Japan.
- Department of Urology, Komatsu Municipal Hospital, Komatsu, Ishikawa, Japan.
ORCID-Profile: Akane Yamaguchi, Chie Matsushita, Masaki Watanabe, Shuya Kandori, Hiromitsu Negoro, Yasuhide Kitagawa, Hiroyuki Nishiyama
Zitieren
APA
Yamaguchi, A., Kikuchi, M., Miwa, K., Matsushita, C., Watanabe, M., Niimura, T., Kandori, S., Negoro, H., Kitagawa, Y., & Nishiyama, H. (2025). Improving Visualization via Polytetrafluoroethylene Mesh in 3D Computed Tomography Imaging After Laparoscopic Sacrocolpopexy. International Journal of Urology. https://doi.org/10.1111/iju.70186
Vancouver
Yamaguchi A, Kikuchi M, Miwa K, Matsushita C, Watanabe M, Niimura T, et al. Improving Visualization via Polytetrafluoroethylene Mesh in 3D Computed Tomography Imaging After Laparoscopic Sacrocolpopexy. International Journal of Urology. 2025. doi:10.1111/iju.70186
BibTeX
@article{Yamaguchi2025,
author = {Yamaguchi, Akane and Kikuchi, Moemi and Miwa, Kosei and Matsushita, Chie and Watanabe, Masaki and Niimura, Tokiko and Kandori, Shuya and Negoro, Hiromitsu and Kitagawa, Yasuhide and Nishiyama, Hiroyuki},
title = {Improving Visualization via Polytetrafluoroethylene Mesh in 3D Computed Tomography Imaging After Laparoscopic Sacrocolpopexy},
journal = {International Journal of Urology},
year = {2025},
doi = {10.1111/iju.70186}
}
EUVIMED