Operative Times, Costs and Patient‐Related Outcome Measures in Vertical Ridge Augmentation With Customised Reinforced PTFE Mesh Versus CAD / CAM Titanium Mesh: Secondary Analysis of a Randomised Clinical Trial
Journal of Clinical Periodontology · 2025-07 · 52 (7) · 971-982
DOI: 10.1111/jcpe.14185 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of Clinical Periodontology, online erschienen am 26.05.2025. Verfasst von Alessandro Cucchi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Private Practice, Bologna, Italy. Hauptthemen laut MEDLINE: Alveolar Ridge Augmentation, Computer-Aided Design, Operative Time, Polytetrafluoroethylene. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aim
This secondary analysis of a randomised clinical trial aimed to investigate vertical ridge augmentation (VRA) by comparing complication rates (primary outcome), times, costs and patient‐reported outcome measures (PROMs) between customised Ti‐reinforced PTFE mesh and customised CAD/CAM titanium mesh. Materials and Methods Patients with vertical bone defects were randomly assigned to alveolar bone augmentation using either Ti‐PTFE mesh or Ti mesh (T0). After 6–9 months, barriers were removed, and computer‐guided surgery was performed to place implants in the augmented sites (T1). Complications, times, costs and PROMs (anxiety, pain, anti‐inflammatory drug dosage, limitations in daily functions) were assessed and analysed.
Results
Forty‐eight of 50 patients completed the bone augmentation surgery as per protocol. The estimated difference in healing complications was −0.04% (CI: −0.22 to 0.13), confirming the non‐inferiority of Ti meshes to PTFE meshes. The estimated differences were −3.50 min (CI: −23.49 to 16.49) for total operative time ( p = 0.688); €17.37 (−77.25 to 111.99) for costs ( p = 0.130); −0.17 (CI: −0.80 to 0.47) for anti‐inflammatory drug usage ( p = 0.299); 0.56 (CI: −1.97 to 0.85) for pain levels ( p = 0.565); and −0.13 (CI: −0.61 to 0.36) for limitations in daily functions ( p = 0.528), on the day after surgery.
Conclusion
Outcomes were favourable, which encourage the use of both medical devices with low complication rates and both digital approaches, resulting in favourable operative times and PROMs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Private Practice, Bologna, Italy.
- Department of Experimental and Clinic Medicine, University of Florence, Florence, Italy.
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA.
- Department of Neuroscience and Reproductive and Odontostomatological Sciences, 'Federico II' University of Naples, Naples, Italy.
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy.
ORCID-Profile: Alessandro Cucchi, Debora Franceschi
Zitieren
APA
Cucchi, A., Bettini, S., Tedeschi, L., Franceschi, D., Urban, I., Fiorino, A., & Corinaldesi, G. (2025). Operative Times, Costs and Patient‐Related Outcome Measures in Vertical Ridge Augmentation With Customised Reinforced PTFE Mesh Versus CAD / CAM Titanium Mesh: Secondary Analysis of a Randomised Clinical Trial. Journal of Clinical Periodontology, 52(7), 971-982. https://doi.org/10.1111/jcpe.14185
Vancouver
Cucchi A, Bettini S, Tedeschi L, Franceschi D, Urban I, Fiorino A, et al. Operative Times, Costs and Patient‐Related Outcome Measures in Vertical Ridge Augmentation With Customised Reinforced PTFE Mesh Versus CAD / CAM Titanium Mesh: Secondary Analysis of a Randomised Clinical Trial. Journal of Clinical Periodontology. 2025;52(7):971-982. doi:10.1111/jcpe.14185
BibTeX
@article{Cucchi2025,
author = {Cucchi, Alessandro and Bettini, Sofia and Tedeschi, Lucia and Franceschi, Debora and Urban, Istvan and Fiorino, Antonino and Corinaldesi, Giuseppe},
title = {Operative Times, Costs and Patient‐Related Outcome Measures in Vertical Ridge Augmentation With Customised Reinforced PTFE Mesh Versus CAD / CAM Titanium Mesh: Secondary Analysis of a Randomised Clinical Trial},
journal = {Journal of Clinical Periodontology},
year = {2025},
volume = {52},
number = {7},
pages = {971--982},
doi = {10.1111/jcpe.14185}
}