Expanded polytetrafluoroethylene mesh in chest-wall reconstruction: A 27-year experience
The Journal of Thoracic and Cardiovascular Surgery · 2025-01 · 169 (1) · 303-313.e2
DOI: 10.1016/j.jtcvs.2024.05.026 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2025-01. Verfasst von Aida K Sarcon und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of General Surgery, Department of Surgery, Mayo Clinic, Rochester, Minn. Hauptthemen laut MEDLINE: Polytetrafluoroethylene, Surgical Mesh, Reoperation, Thoracic Wall. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Mayo Clinic.
Abstract (Originalsprache)
OBJECTIVE: The study objective was to evaluate the success of expanded polytetrafluoroethylene mesh in chest-wall reconstruction. METHODS: We retrospectively reviewed patients who underwent expanded polytetrafluoroethylene (Gore-Tex) chest-wall reconstruction. The main outcome was a mesh-related event, defined as a mesh-related reoperation (eg, mesh infection requiring debridement with/without explant, tumor recurrence with explant) or structural dehiscence/mesh loosening with/without a hernia. Demographics and surgical outcomes were reported. RESULTS: A total of 246 reconstructions met inclusion (1994-2021). Fifty-five reconstructions (22.4%) had mesh-related events within a median of 1.08 years (interquartile range, 0.08-4.53) postoperatively; those without had a stable chest for a median of 3.9 years (interquartile range, 1.59-8.23, P < .001). Forty-one meshes (16.6%) became infected, requiring reoperation. Eighty-eight percent (36/41) were completely explanted; 8.3% (3/36) required additional mesh placement. Predictors of mesh-related events were prior chest-wall radiation (odds ratio, 9.73, CI, 3.47-30.10, P < .001), higher body mass index (odds ratio, 1.08, CI, 1.01-1.16, P = .019), and larger defects (odds ratio, 1.48, CI, 1.02-2.17, P = .042). The risk of mesh-related events with obesity was higher with prior chest-wall radiation. CONCLUSIONS: Most patients (78%) with an expanded polytetrafluoroethylene mesh had a stable reconstruction after a median of 4 years. Obesity, larger defects, and prior chest-wall radiation were associated with a higher risk of a mesh-related event mostly due to mesh infections. Seventeen percent of reconstructions had reoperation for mesh infection; 88% were completely explanted. Only 8% required replacement mesh, suggesting that experienced surgeons can safely manage them without replacement. Future studies should compare various meshes for high-risk patients to help guide the optimal mesh selection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of General Surgery, Department of Surgery, Mayo Clinic, Rochester, Minn.
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minn.
- Division of Plastic and Reconstructive Surgery, Department of Surgery, Mayo Clinic, Rochester, Minn.
- Division of General Surgery, Department of Surgery, Mayo Clinic, Phoenix, Ariz.
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minn; Division of Plastic and Reconstructive Surgery, Department of Surgery, Mayo Clinic, Rochester, Minn.
- Division of Thoracic Surgery and Plastic Surgery, Department of Surgery, Mayo Clinic, Rochester, Minn. Electronic address: Shen.KRobert@mayo.edu.
Förderung
- Mayo Clinic
Zitieren
APA
Sarcon, A. K., Selim, O. A., Mullen, B. L., Mundell, B. F., Moran, S. L., & Shen, K. R. (2025). Expanded polytetrafluoroethylene mesh in chest-wall reconstruction: A 27-year experience. The Journal of Thoracic and Cardiovascular Surgery, 169(1), 303-313.e2. https://doi.org/10.1016/j.jtcvs.2024.05.026
Vancouver
Sarcon AK, Selim OA, Mullen BL, Mundell BF, Moran SL, Shen KR. Expanded polytetrafluoroethylene mesh in chest-wall reconstruction: A 27-year experience. The Journal of Thoracic and Cardiovascular Surgery. 2025;169(1):303-313.e2. doi:10.1016/j.jtcvs.2024.05.026
BibTeX
@article{Sarcon2025,
author = {Sarcon, Aida K and Selim, Omar A and Mullen, Barbara L and Mundell, Benjamin F and Moran, Steven L and Shen, K Robert},
title = {Expanded polytetrafluoroethylene mesh in chest-wall reconstruction: A 27-year experience},
journal = {The Journal of Thoracic and Cardiovascular Surgery},
year = {2025},
volume = {169},
number = {1},
pages = {303--313.e2},
doi = {10.1016/j.jtcvs.2024.05.026}
}
EUVIMED