Fachartikel in der Zeitschrift International Journal of Laboratory Hematology, 2023. Verfasst von Koji Tsuchiya und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Juntendo University Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Bone Marrow, Hematology. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sysmex Corporation, Japan Society for the Promotion of Science Grants-in Aid for Scientific Research.
Abstract (Originalsprache)
Introduction
This study evaluated the feasibility of the Sysmex XN‐3000 automated hematology analyzer for the assessment of total nucleated cells (TNC) and bone marrow (BM) cell density in routine bone marrow aspiration (BMA) samples.
Methods
A total of 54 BMA samples from 39 hematological patients were evaluated. The number of megakaryocytes was calculated by a specific gating algorithm using the body fluid mode of the WBC differential (WDF) channel. Lipid contents were calculated through a newly developed algorithm utilizing the WDF channel. The ratio of lipid particles over TNCs by the WNR channel was compared with the BM cellularity assessed by the BM biopsy. The myeloid/erythroid ( M / E ) ratio was calculated by measuring the number of myeloid cells in the WDF channel and the number of nucleated red blood cells (NRBCs) in the WNR channel.
Results
XN‐3000 counts and microscopic results showed a linear correlation in TNC ( R 2 = .98, p < .001), megakaryocytes ( R 2 = .59, p = .002), NRBC ( R 2 = .84, p < .001), and M / E ratio ( R 2 = .59, p < .001). There were significant differences in the lipid/TNC ratios of hypercellular, normocellular, and hypocellular BMs measured by XN‐3000 ( p < .001). Receiver‐operating characteristic analysis detected cut‐off values of the lipid/TNC ratio of >0.4054 for hypoplasia and
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory, Juntendo University Hospital, Tokyo, Japan.
- Department of Next Generation Hematology Laboratory Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
- Sysmex Corporation, Kobe, Japan.
- Department of Clinical Laboratory Medicine, Juntendo University Graduate School of Medicine, Tokyo, Japan.
- Department of Hematology, Juntendo University School of Medicine, Tokyo, Japan.
ORCID-Profile: Koji Tsuchiya, Tomohiko Ai, Yuki Horiuchi
Förderung
- Sysmex Corporation
- Japan Society for the Promotion of Science Grants-in Aid for Scientific Research
Zitieren
APA
Tsuchiya, K., Kimura, K., Ai, T., Yamamoto, T., Nagasaka, K., Takemura, H., Edahiro, Y., Saito, K., Horiuchi, Y., Misawa, S., Takaku, T., Ando, J., Ando, M., Miida, T., Uchihashi, K., & Tabe, Y. (2023). Evaluation of bone marrow aspirates using the automated hematology analyzer Sysmex XN ‐3000. International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.14058
Vancouver
Tsuchiya K, Kimura K, Ai T, Yamamoto T, Nagasaka K, Takemura H, et al. Evaluation of bone marrow aspirates using the automated hematology analyzer Sysmex XN ‐3000. International Journal of Laboratory Hematology. 2023. doi:10.1111/ijlh.14058
BibTeX
@article{Tsuchiya2023,
author = {Tsuchiya, Koji and Kimura, Konobu and Ai, Tomohiko and Yamamoto, Takamasa and Nagasaka, Kaori and Takemura, Hiroyuki and Edahiro, Yoko and Saito, Kaori and Horiuchi, Yuki and Misawa, Shigeki and Takaku, Tomoiku and Ando, Jun and Ando, Miki and Miida, Takashi and Uchihashi, Kinya and Tabe, Yoko},
title = {Evaluation of bone marrow aspirates using the automated hematology analyzer Sysmex XN ‐3000},
journal = {International Journal of Laboratory Hematology},
year = {2023},
doi = {10.1111/ijlh.14058}
}
EUVIMED