EUVIMEDEUVIMED entdecken
Crossref

White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC ‐80

Narin Khongjaroensakun, Nutdanai Chaothai, Laksika Chamchomdao, Katesaree Suriyachand, Karan Paisooksantivatana iD

International Journal of Laboratory Hematology · 2023

DOI: 10.1111/ijlh.14119 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Laboratory Hematology, 2023. Verfasst von Narin Khongjaroensakun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand. Hauptthemen laut MEDLINE: Leukocytes, Hematology. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The manual differential count has been recognized for its disadvantages, including large interobserver variability and labor intensiveness. In this light, automated digital cell morphology analyzers have been increasingly adopted in hematology laboratories for their robustness and convenience. This study aims to evaluate the white blood cell differential performance of the Mindray MC‐80, the new automated digital cell morphology analyzer.

Methods

The cell identification performance of Mindray MC‐80 was evaluated for sensitivity and specificity using pre‐classification and post‐classification of each cell class. The method comparison study used manual differentials as the gold standard for calculating Pearson correlation, Passing‐Bablok regression, and Bland–Altman analysis. In addition, the precision study was performed and evaluated.

Results

The precision was within the acceptable limit for all cell classes. Overall, the specificity of cell identification was higher than 95% for all cell classes. The sensitivity was greater for 95% for most cell classes, except for myelocytes (94.9%), metamyelocytes (90.9%), reactive lymphocytes (89.7%), and plasma cells (60%). Pre‐classification and post‐classification results correlated well with the manual differential results for all the cell types investigated. The regression coefficients were greater than 0.9 for most cell classes except for promyelocytes, metamyelocytes, basophils, and reactive lymphocytes.

Conclusion

The performance of Mindray MC‐80 for white blood cell differentials is reliable and seems to be acceptable even in abnormal samples. However, the sensitivity is less than 95% for certain abnormal cell types, so the user should be aware of this limitation where such cells are suspected.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LeukocytesHematologyHumansLeukocyte CountReproducibility of ResultsBlood Cell CountPlasma Cells

Stichwörter der Autor:innen

MC80WBC differentialsdigital morphologylaboratory automationperformance

Autor:innen und Institutionen

  • Department of Pathology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand.

ORCID-Profile: Karan Paisooksantivatana

Zitieren

APA

Khongjaroensakun, N., Chaothai, N., Chamchomdao, L., Suriyachand, K., & Paisooksantivatana, K. (2023). White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC ‐80. International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.14119

Vancouver

Khongjaroensakun N, Chaothai N, Chamchomdao L, Suriyachand K, Paisooksantivatana K. White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC ‐80. International Journal of Laboratory Hematology. 2023. doi:10.1111/ijlh.14119

BibTeX
@article{Khongjaroensakun2023,
  author = {Khongjaroensakun, Narin and Chaothai, Nutdanai and Chamchomdao, Laksika and Suriyachand, Katesaree and Paisooksantivatana, Karan},
  title = {White blood cell differentials performance of a new automated digital cell morphology analyzer: Mindray MC ‐80},
  journal = {International Journal of Laboratory Hematology},
  year = {2023},
  doi = {10.1111/ijlh.14119}
}
Kostenlos starten →