EUVIMEDObjevte EUVIMED
Crossref

Predominance of Radiographical Femoral Component Loosening Signs in Total Knee Arthroplasty for Hemophilic Arthropathy

Başak Koç, Bülent Zülfikar, Ufuk Arzu, İsmail Tarık Atasoy, Mert Ege, Gökhan Polat

Haemophilia · 2026

DOI: 10.1111/hae.70155 ↗

At a glance

Journal article in Haemophilia, 2026. Written by Başak Koç and 5 co-authors. Institution: Institute of Oncology, Department of Hereditary Bleeding Disorders Unit, Istanbul University, Istanbul, Turkey. Major MEDLINE topics: Arthroplasty, Replacement, Knee, Prosthesis Failure, Femur, Hemophilia A. 20 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Aim

To compare the frequency and timing of femoral‐ versus tibial‐sided radiographic radiolucencies after posterior‐stabilized TKA in people with haemophilia (PwH) versus non‐haemophilic controls.

Methods

A retrospective analysis was conducted of all primary posterior‐stabilised total knee arthroplasties (TKA) performed in the centre between December 2003 and December 2018. Patients in Group 1 ( n = 53) were age‐ and implant‐matched to controls without haemophilia in Group 2 ( n = 58). Radiographs were obtained at 3, 6 and annually to 5 years. Loosening was defined as progressive radiolucent lines >1 mm and/or migration/osteolysis, adjudicated by two blinded surgeons.

Results

Mean age at surgery was 35.7 ± 9.2 years in Group 1 and 60.5 ± 11.8 years in Group 2 ( p < 0.001). Femoral component loosening occurred in 22.6% of PwH versus 5.2% of controls ( p = 0.011), whereas tibial loosening rates were 11.3% versus 8.6% ( p = 0.755). Mean time to femoral loosening was 27.6 ± 16.8 months (Group 1) versus 31.3 ± 13.9 months (Group 2; p = 0.788), and to tibial loosening was 20.4 ± 18.2 months versus 9.6 ± 9.5 months ( p = 0.134). Cox regression showed no significant hazard difference for femoral loosening (HR 0.99, 95% CI 0.93–1.05; p = 0.693). Post hoc power for detecting femoral loosening differences was ∼80%.

Conclusions

PwH undergoing TKA showed a higher frequency of femoral‐sided radiographic radiolucencies. These findings should be interpreted as potential predisposition to early loosening. Tibial findings were comparable between groups.

Subjects

MeSH terms (MEDLINE)

Arthroplasty, Replacement, KneeProsthesis FailureFemurHemophilia AKnee ProsthesisKnee JointRetrospective StudiesProspective StudiesTibiaCase-Control StudiesFollow-Up StudiesHumansMaleFemaleYoung AdultAdultMiddle AgedAged

Authors and institutions

  • Institute of Oncology, Department of Hereditary Bleeding Disorders Unit, Istanbul University, Istanbul, Turkey.
  • Department of Orthopedics and Traumatology, Marmara University Pendik Research and Training Hospital, Istanbul, Turkey.
  • Department of Orthopedics and Traumatology, Istanbul Medical Faculty, Istanbul University, Istanbul, Turkey.

Cite

APA

Koç, B., Zülfikar, B., Arzu, U., Atasoy, İ. T., Ege, M., & Polat, G. (2026). Predominance of Radiographical Femoral Component Loosening Signs in Total Knee Arthroplasty for Hemophilic Arthropathy. Haemophilia. https://doi.org/10.1111/hae.70155

Vancouver

Koç B, Zülfikar B, Arzu U, Atasoy İT, Ege M, Polat G. Predominance of Radiographical Femoral Component Loosening Signs in Total Knee Arthroplasty for Hemophilic Arthropathy. Haemophilia. 2026. doi:10.1111/hae.70155

BibTeX
@article{Ko2026,
  author = {Koç, Başak and Zülfikar, Bülent and Arzu, Ufuk and Atasoy, İsmail Tarık and Ege, Mert and Polat, Gökhan},
  title = {Predominance of Radiographical Femoral Component Loosening Signs in Total Knee Arthroplasty for Hemophilic Arthropathy},
  journal = {Haemophilia},
  year = {2026},
  doi = {10.1111/hae.70155}
}
Start for free →