EUVIMEDEUVIMED entdecken
Crossref

Third-Generation Flexible Metaphyseal Cones in Revision Total Knee Arthroplasty: Minimum Two-Year Follow-up

Lindsey K Meding, R Michael Meneghini, Leonard T Buller, Evan R Deckard, John B Meding

The Journal of Arthroplasty · 2026

DOI: 10.1016/j.arth.2026.03.017 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2026. Verfasst von Lindsey K Meding und 4 weiteren Autor:innen. Beteiligte Einrichtung: Indiana Joint Replacement Institute, Noblesville, Indiana. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Knee Joint. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 85 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Porous metal cones are commonly utilized in revision total knee arthroplasty (rTKA) to manage severe bone loss. Flexible metaphyseal cones (FMCs) allow for macrodeformation, more uniform stress distribution, and diminished peak stresses to the compromised cortical bone, potentially reducing fracture risk during impaction. This study aimed to evaluate the early outcomes of FMCs used to treat severe bone loss in rTKA. METHODS: There were 241 FMCs inserted during 200 rTKAs. A combination of femoral and tibial FMCs was used in 41 knees. The most common reasons for revision were flexion instability (90 cases), aseptic loosening with or without osteolysis (55 cases), and reimplantation postinfection (27 cases). The mean age at operation was 68 years (range, 37 to 82). The Anderson Orthopaedic Research Institute bone loss classification was used. Serial radiographs were reviewed for evidence of loosening or osseointegration, and survivorship was determined. The mean follow-up was 3 years (range, 2 to 4.5). RESULTS: At final follow-up, no radiolucent lines were identified around the FMCs. Survivorship was 98% for any revision, 99% for aseptic revision, and 100% for aseptic loosening. Excluding infection, all remaining FMCs (240 cones) demonstrated evidence of stable fixation. There were two intraoperative fractures (1%) that occurred (one femur and one tibia), both in knees with type 2B defects, with only one fracture associated with cone insertion (0.5%). There were three re-revisions (1.5%). There was one knee (0.5%) that was explanted for a recurrent infection at 6 months; one underwent irrigation and debridement with polyethylene exchange for infection (postreimplantation), and a third was revised with polyethylene exchange for arthrofibrosis. CONCLUSIONS: To our knowledge, this is the first study evaluating the clinical results exclusively for noncustomized, third-generation FMCs in rTKA. The FMCs provide stable fixation at early follow-up, and their ability to deform during impaction appears advantageous with a low rate of intraoperative fracture.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisKnee JointHumansReoperationFollow-Up StudiesProsthesis FailureAgedAged, 80 and overMiddle AgedAdultFemaleMaleProsthesis DesignRadiographyTibiaTreatment OutcomeFemur

Stichwörter der Autor:innen

flexible conesflexible metaphyseal conesfractureinsertionmetaphyseal conesrevision total knee arthroplastythird generation cones

Autor:innen und Institutionen

  • Indiana Joint Replacement Institute, Noblesville, Indiana.
  • Indiana Joint Replacement Institute, Noblesville, Indiana; The Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis IN, The IU Hip and Knee Center, Fishers, Indiana.
  • The Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis IN, The IU Hip and Knee Center, Fishers, Indiana.

Zitieren

APA

Meding, L. K., Meneghini, R. M., Buller, L. T., Deckard, E. R., & Meding, J. B. (2026). Third-Generation Flexible Metaphyseal Cones in Revision Total Knee Arthroplasty: Minimum Two-Year Follow-up. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2026.03.017

Vancouver

Meding LK, Meneghini RM, Buller LT, Deckard ER, Meding JB. Third-Generation Flexible Metaphyseal Cones in Revision Total Knee Arthroplasty: Minimum Two-Year Follow-up. The Journal of Arthroplasty. 2026. doi:10.1016/j.arth.2026.03.017

BibTeX
@article{Meding2026,
  author = {Meding, Lindsey K and Meneghini, R Michael and Buller, Leonard T and Deckard, Evan R and Meding, John B},
  title = {Third-Generation Flexible Metaphyseal Cones in Revision Total Knee Arthroplasty: Minimum Two-Year Follow-up},
  journal = {The Journal of Arthroplasty},
  year = {2026},
  doi = {10.1016/j.arth.2026.03.017}
}
Kostenlos starten →