Characterisation of Geological Samples with Dual‐Energy XCT : A Comparison of Three Different Scanners
Geostandards and Geoanalytical Research · 2025-09 · 49 (3) · 645-664
DOI: 10.1111/ggr.12608 ↗Kurz gefasst
Fachartikel in der Zeitschrift Geostandards and Geoanalytical Research, online erschienen am 28.04.2025. Verfasst von Margherita Martini und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canada Research Chairs, Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.
Abstract (Originalsprache)
The stoichiometric calibration method for dual‐energy computed tomography (DECT) can be used in geosciences to characterise materials based on their effective atomic number ( Z eff ) and their electron density ( ρ e ) without previous knowledge of the incident X‐ray beam. A stoichiometrically calibrated DECT method was applied here to measure these two properties on three different sedimentary rocks using three different X‐ray CT instruments to determine which one is best to reveal the chemical composition or the mineralogical variations at the meso‐scale. The three tested instruments: (1) a medical CT, (2) a custom‐built micro‐CT, and (3) a commercial micro‐CT. Several acquisition settings were tested to identify the most suitable parameters for the characterisation the samples. Some parameters such as incident energies, resolution and calibration materials proved to have a significant impact on the accuracy of the characterisation. The determination of a general measurement protocol for geological samples was found to be difficult because of several complicating factors, including the nature of the sample, objectives of the study, and instrumental limitations that influence DECT characterisation. Nonetheless, comparison of the results obtained by the three scanners brings out the key parameters to be considered to perform a useful rock sample characterisation with DECT.
Förderung
- Canada Research Chairs
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation
Zitieren
APA
Martini, M., Francus, P., Schröer, L., Buyse, F., Kibleur, P., Cnudde, V., Trotta, L. D. S., & Després, P. (2025). Characterisation of Geological Samples with Dual‐Energy XCT : A Comparison of Three Different Scanners. Geostandards and Geoanalytical Research, 49(3), 645-664. https://doi.org/10.1111/ggr.12608
Vancouver
Martini M, Francus P, Schröer L, Buyse F, Kibleur P, Cnudde V, et al. Characterisation of Geological Samples with Dual‐Energy XCT : A Comparison of Three Different Scanners. Geostandards and Geoanalytical Research. 2025;49(3):645-664. doi:10.1111/ggr.12608
BibTeX
@article{Martini2025,
author = {Martini, Margherita and Francus, Pierre and Schröer, Laurenz and Buyse, Florian and Kibleur, Pierre and Cnudde, Veerle and Trotta, Leonardo Di Schiavi and Després, Philippe},
title = {Characterisation of Geological Samples with Dual‐Energy XCT : A Comparison of Three Different Scanners},
journal = {Geostandards and Geoanalytical Research},
year = {2025},
volume = {49},
number = {3},
pages = {645--664},
doi = {10.1111/ggr.12608}
}
EUVIMED