Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT

Martine Remy-Jardin, Lucas Guiffault, Idir Oufriche, Alain Duhamel, Thomas Flohr, Bernhard Schmidt, Jacques Remy

European Radiology · 05.07.2024 · 34 (12) · 7831-7844

DOI: 10.1007/s00330-024-10888-0 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Radiology, online erschienen am 05.07.2024. Verfasst von Martine Remy-Jardin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Imaging, University Hospital Center of Lille, LILLE, France. dr.remy.jardin@gmail.com. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the quality of lung perfusion imaging obtained with photon-counting-detector CT (PCD-CT) in comparison with dual-source, dual-energy CT (DECT). METHODS: Seventy-one consecutive patients scanned with PCD-CT were compared to a paired population scanned with dual-energy on a 3rd-generation DS-CT scanner using (a) for DS-CT (Group 1): collimation: 64 × 0.6 × 2 mm; pitch: 0.55; (b) for PCD-CT (Group 2): collimation: 144 × 0.4 mm; pitch: 1.5; single-source acquisition. The injection protocol was similar in both groups with the reconstruction of perfusion images by subtraction of high- and low-energy virtual monoenergetic images. RESULTS: Compared to Group 1, Group 2 examinations showed: (a) a shorter duration of data acquisition (0.93 ± 0.1 s vs 3.98 ± 0.35 s; p < 0.0001); (b) a significantly lower dose-length-product (172.6 ± 55.14 vs 339.4 ± 75.64 mGy·cm; p < 0.0001); and (c) a higher level of objective noise (p < 0.0001) on mediastinal images. On perfusion images: (a) the mean level of attenuation did not differ (p = 0.05) with less subjective image noise in Group 2 (p = 0.049); (b) the distribution of scores of fissure visualization differed between the 2 groups (p < 0.0001) with a higher proportion of fissures sharply delineated in Group 2 (n = 60; 84.5% vs n = 26; 26.6%); (c) the rating of cardiac motion artifacts differed between the 2 groups (p < 0.0001) with a predominance of examinations rated with mild artifacts in Group 2 (n = 69; 97.2%) while the most Group 1 examinations showed moderate artifacts (n = 52; 73.2%). CONCLUSION: PCD-CT acquisitions provided similar morphologic image quality and superior perfusion imaging at lower radiation doses. CLINICAL RELEVANCE STATEMENT: The improvement in the overall quality of perfusion images at lower radiation doses opens the door for wider applications of lung perfusion imaging in clinical practice. KEY POINTS: The speed of data acquisition with PCD-CT accounts for mild motion artifacts. Sharply delineated fissures are depicted on PCD-CT perfusion images. High-quality perfusion imaging was obtained with a 52% dose reduction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedHumansFemaleMaleMiddle AgedAgedPhotonsPerfusion ImagingLungRadiography, Dual-Energy Scanned ProjectionAdultRadiation DosageAged, 80 and overRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Chest-CTDual-source dual-energy CTPerfusion imagingPhoton-counting CTRadiation dose

Autor:innen und Institutionen

  • Department of Thoracic Imaging, University Hospital Center of Lille, LILLE, France. dr.remy.jardin@gmail.com.
  • ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, LILLE, France. dr.remy.jardin@gmail.com.
  • IMALLIANCE-Haut-de-France, Valenciennes, France. dr.remy.jardin@gmail.com.
  • Department of Thoracic Imaging, University Hospital Center of Lille, LILLE, France.
  • ULR 2694 METRICS Evaluation des technologies de santé et des pratiques médicales, LILLE, France.
  • Department of Biostatistics, University of Lille, CHU Lille, LILLE, France.

Zitieren

APA

Remy-Jardin, M., Guiffault, L., Oufriche, I., Duhamel, A., Flohr, T., Schmidt, B., & Remy, J. (2024). Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT. European Radiology, 34(12), 7831-7844. https://doi.org/10.1007/s00330-024-10888-0

Vancouver

Remy-Jardin M, Guiffault L, Oufriche I, Duhamel A, Flohr T, Schmidt B, et al. Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT. European Radiology. 2024;34(12):7831-7844. doi:10.1007/s00330-024-10888-0

BibTeX
@article{RemyJardin2024,
  author = {Remy-Jardin, Martine and Guiffault, Lucas and Oufriche, Idir and Duhamel, Alain and Flohr, Thomas and Schmidt, Bernhard and Remy, Jacques},
  title = {Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT},
  journal = {European Radiology},
  year = {2024},
  volume = {34},
  number = {12},
  pages = {7831--7844},
  doi = {10.1007/s00330-024-10888-0}
}
Kostenlos starten →