Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions
Equine Veterinary Journal · 2025
DOI: 10.1111/evj.70109 ↗At a glance
Journal article in Equine Veterinary Journal, 2025. Written by Karsten Key and 4 co-authors. Institution: Keydiagnostics, Fredensborg, Denmark. Major MEDLINE topics: Algorithms, Gait, Gait Analysis. Cited 1 times so far (Crossref); 34 references. The full text is freely available (open access, CC BY 4.0). Funded by: KeyDiagnostics ApS.
Abstract (original language)
Background
Computer vision‐based algorithms offer accessible alternatives for equine gait analysis but require thorough assessment under diverse conditions.
Objectives
To evaluate a proprietary vision‐based algorithm's reliability in measuring vertical displacement signals (VDS) at the eye, withers and croup, alongside groundline estimation, for horses trotting on straight lines and circles under field conditions. Study Design Cross‐sectional comparative study evaluating agreement, variability and reliability of a markerless computer vision algorithm.
Methods
We obtained 67 handheld iPhone recordings from 37 horses. A vision‐based algorithm and independent manual annotation produced 2D anatomical keypoints on all frames of the recordings, which were processed to estimate a groundline and compute VDS and stride‐based maxima (Maxdiff) and minima (Mindiff) vertical differences. Mean signed error (MSE), mean absolute error (MAE) and Bland–Altman plots were used to compare detected and annotated data.
Results
The frame level vertical keypoint accuracy was 4.5 mm (eye), 5.5 mm (croup) and 11.8 mm (withers), and the manual annotation error was averaged at 2.7 mm. At the stride level ( n = 1556), the overall mean absolute errors (MAEs) for both Maxdiff and Mindiff were 4.3 mm. The eye keypoint exhibited the lowest errors (2.9 mm Maxdiff, 3.0 mm Mindiff), while the withers error was 5.5 mm for both Maxdiff and Mindiff, and the croup showed 4.3 mm (Maxdiff) and 4.4 mm (Mindiff). Trial‐level ( n = 67) analysis, with below optimal number of strides per trial in this study, revealed lower overall absolute differences (Eye: 2.3 mm, Withers: 3.7 mm, Croup: 2.7 mm), indicating consistent performance across multiple strides. Subjective lameness scoring aligned with objective measures with some variation. Main Limitations Groundline estimation accuracy was stress‐tested on treadmill data in another study. Further clinical comparison with established gait analysis systems is recommended.
Conclusions
The algorithm robustly measured vertical displacements under varied conditions.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Keydiagnostics, Fredensborg, Denmark.
- iKeyVet, Fredensborg, Denmark.
- Department of Veterinary Clinical Sciences, University of Copenhagen, Copenhagen, Denmark.
ORCID profiles: Karsten Key, Sabrina Skov Hansen
Funding
- KeyDiagnostics ApS
Cite
APA
Key, K., Berg, K., Kirkegaard, J., Andresen, K. R., & Skov Hansen, S. (2025). Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions. Equine Veterinary Journal. https://doi.org/10.1111/evj.70109
Vancouver
Key K, Berg K, Kirkegaard J, Andresen KR, Skov Hansen S. Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions. Equine Veterinary Journal. 2025. doi:10.1111/evj.70109
BibTeX
@article{Key2025,
author = {Key, Karsten and Berg, Katja and Kirkegaard, Jakob and Andresen, Kristian Ringkjær and Skov Hansen, Sabrina},
title = {Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions},
journal = {Equine Veterinary Journal},
year = {2025},
doi = {10.1111/evj.70109}
}
EUVIMED