Validation of a handheld smartphone markerless gait‐analysis tool using an estimated groundline in horses
Equine Veterinary Journal · 2026
DOI: 10.1002/evj.70149 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Equine Veterinary Journal, 2026. Verfasst von Karsten Key und 4 weiteren Autor:innen. Beteiligte Einrichtung: Keydiagnostics (RealHorse®), Fredensborg, Denmark. Hauptthemen laut MEDLINE: Smartphone, Gait, Gait Analysis. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
A handheld smartphone‐based computer vision algorithm (RealHorse® [RH]) offers accessible alternatives for equine gait analysis but requires validation against a gold‐standard three‐dimensional multicamera optical motion capture system (Qualisys® [QS]).
Objectives
To evaluate the accuracy and precision of RH in measuring vertical displacement signals (VDS) at the eye, withers, back and croup in horses trotting on a straight line and on a circle. Study Design Cross‐sectional comparative validation study of a markerless computer vision algorithm.
Methods
Fifty‐nine horses were recorded while trotting on a straight line and 24 were lunged on a circle. RH detected two‐dimensional anatomical keypoints on each frame, which were used to estimate a dynamic groundline and compute ground relative VDS with stride‐based difference in maxima (Maxdiff) and minima (Mindiff). QS provided synchronous ground‐relative VDS reference values. Agreement was evaluated using mean signed error, mean absolute error and Bland–Altman analysis.
Results
On the straight line ( n = 2620 strides), the pooled stride‐level MAE for Maxdiff and Mindiff was 3.8 mm. Keypoint‐specific errors were 5.1 mm (eye), 4.3 mm (withers) and 3.0 mm (croup). On the circle ( n = 2419 strides), pooled stride‐level error increased to 5.5 mm. Trial‐level analysis ( n = 58 trials) showed much lower errors: 1.4 mm for both eye and withers and 1.1 mm for croup. On the circle ( n = 24 trials), trial‐level errors were higher, with 2.8 mm for the eye, 1.8 mm for the withers and 3.3 mm for the croup. The back keypoint consistently showed the lowest errors across both stride and trial levels. Main Limitations RH measurements of the croup Mindiff during circling resulted in higher values and showed the largest error.
Conclusions
RH measured vertical displacement of all keypoints with high accuracy and precision (trial‐level MAE 1.1–1.4 mm straight, 1.8–3.3 mm circle), supporting its use for equine gait analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Keydiagnostics (RealHorse®), Fredensborg, Denmark.
- iKeyVet®, Fredensborg, Denmark.
- Department of Veterinary Clinical Sciences, University of Copenhagen, Copenhagen, Denmark.
ORCID-Profile: Karsten Key, Sabrina Skov Hansen
Zitieren
APA
Key, K., Kirkegaard, J., Berg, K., Andresen, K. R., & Skov Hansen, S. (2026). Validation of a handheld smartphone markerless gait‐analysis tool using an estimated groundline in horses. Equine Veterinary Journal. https://doi.org/10.1002/evj.70149
Vancouver
Key K, Kirkegaard J, Berg K, Andresen KR, Skov Hansen S. Validation of a handheld smartphone markerless gait‐analysis tool using an estimated groundline in horses. Equine Veterinary Journal. 2026. doi:10.1002/evj.70149
BibTeX
@article{Key2026,
author = {Key, Karsten and Kirkegaard, Jakob and Berg, Katja and Andresen, Kristian Ringkjær and Skov Hansen, Sabrina},
title = {Validation of a handheld smartphone markerless gait‐analysis tool using an estimated groundline in horses},
journal = {Equine Veterinary Journal},
year = {2026},
doi = {10.1002/evj.70149}
}
EUVIMED