Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions
Equine Veterinary Journal · 2025
DOI: 10.1111/evj.70109 ↗Kurz gefasst
Fachartikel in der Zeitschrift Equine Veterinary Journal, 2025. Verfasst von Karsten Key und 4 weiteren Autor:innen. Beteiligte Einrichtung: Keydiagnostics, Fredensborg, Denmark. Hauptthemen laut MEDLINE: Algorithms, Gait, Gait Analysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: KeyDiagnostics ApS.
Abstract (Originalsprache)
Background
Computer vision‐based algorithms offer accessible alternatives for equine gait analysis but require thorough assessment under diverse conditions.
Objectives
To evaluate a proprietary vision‐based algorithm's reliability in measuring vertical displacement signals (VDS) at the eye, withers and croup, alongside groundline estimation, for horses trotting on straight lines and circles under field conditions. Study Design Cross‐sectional comparative study evaluating agreement, variability and reliability of a markerless computer vision algorithm.
Methods
We obtained 67 handheld iPhone recordings from 37 horses. A vision‐based algorithm and independent manual annotation produced 2D anatomical keypoints on all frames of the recordings, which were processed to estimate a groundline and compute VDS and stride‐based maxima (Maxdiff) and minima (Mindiff) vertical differences. Mean signed error (MSE), mean absolute error (MAE) and Bland–Altman plots were used to compare detected and annotated data.
Results
The frame level vertical keypoint accuracy was 4.5 mm (eye), 5.5 mm (croup) and 11.8 mm (withers), and the manual annotation error was averaged at 2.7 mm. At the stride level ( n = 1556), the overall mean absolute errors (MAEs) for both Maxdiff and Mindiff were 4.3 mm. The eye keypoint exhibited the lowest errors (2.9 mm Maxdiff, 3.0 mm Mindiff), while the withers error was 5.5 mm for both Maxdiff and Mindiff, and the croup showed 4.3 mm (Maxdiff) and 4.4 mm (Mindiff). Trial‐level ( n = 67) analysis, with below optimal number of strides per trial in this study, revealed lower overall absolute differences (Eye: 2.3 mm, Withers: 3.7 mm, Croup: 2.7 mm), indicating consistent performance across multiple strides. Subjective lameness scoring aligned with objective measures with some variation. Main Limitations Groundline estimation accuracy was stress‐tested on treadmill data in another study. Further clinical comparison with established gait analysis systems is recommended.
Conclusions
The algorithm robustly measured vertical displacements under varied conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Keydiagnostics, Fredensborg, Denmark.
- iKeyVet, Fredensborg, Denmark.
- Department of Veterinary Clinical Sciences, University of Copenhagen, Copenhagen, Denmark.
ORCID-Profile: Karsten Key, Sabrina Skov Hansen
Förderung
- KeyDiagnostics ApS
Zitieren
APA
Key, K., Berg, K., Kirkegaard, J., Andresen, K. R., & Skov Hansen, S. (2025). Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions. Equine Veterinary Journal. https://doi.org/10.1111/evj.70109
Vancouver
Key K, Berg K, Kirkegaard J, Andresen KR, Skov Hansen S. Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions. Equine Veterinary Journal. 2025. doi:10.1111/evj.70109
BibTeX
@article{Key2025,
author = {Key, Karsten and Berg, Katja and Kirkegaard, Jakob and Andresen, Kristian Ringkjær and Skov Hansen, Sabrina},
title = {Reliability, agreement and variability of a markerless computer vision algorithm for equine gait analysis under field conditions},
journal = {Equine Veterinary Journal},
year = {2025},
doi = {10.1111/evj.70109}
}
EUVIMED