EUVIMEDEUVIMED entdecken
MetaanalyseSystematische Übersicht

Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis

Kaique Leite de Lima, Lorena Rosa Silva, Thayse Bernardes de Paiva Prado, Maria Alves Garcia Silva, Brunno Santos de Freitas Silva, Fernanda Paula Yamamoto-Silva

Clinical Oral Investigations · 2023

DOI: 10.1007/s00784-022-04797-z ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Clinical Oral Investigations, 2023. Verfasst von Kaique Leite de Lima und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil. Hauptthemen laut MEDLINE: Tooth Fractures, Spiral Cone-Beam Computed Tomography, Fractures, Bone. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 83 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the influence of image acquisition parameters (voxel, FOV, kVp, mA) on the accuracy of cone-beam computed tomography (CBCT) in detecting vertical root fracture (VRF). MATERIAL AND METHODS: Searches were performed in 6 main databases and the gray literature, without restrictions of language or date. Observational clinical studies (OCS) and in vitro-extracted teeth (IV) studies were considered eligible for inclusion when investigating the accuracy (sensitivity, specificity) of CBCT in detecting VRF in human teeth. The risk of bias was assessed using QUADAS-2, and a meta-analysis was performed using Review Manager v5.4 software and Jamovi software v1.6. RESULTS: A total of 60 out of 132 articles was included after fulfilling the eligibility criteria. Of these, 54 were IV studies while 6 were OCS. In the IV studies, it was seen that smaller FOV sizes tended to present higher accuracy values. The meta-analysis of the 6 OCS showed that the overall sensitivity and specificity values for 0.08 mm and 0.1 mm voxels were greater (0.84 and 0.79, respectively) than the sensitivity and specificity values for 0.125 mm and 0.2 mm voxels (0.70 and 0.55, respectively). CONCLUSIONS: Despite the uncertain risk of bias found for the IV and OCS studies, smaller voxel and FOV sizes seem to provide more accurate VRF detection values when using CBCT. CLINICAL RELEVANCE: This information is crucial for supporting the clinician when prescribing CBCT in cases of a clinical suspicion of VRF, and contributes to the personalization of the CBCT prescription, thereby ensuring greater accuracy in the VRF diagnosis. Registration This protocol was registered at the PROSPERO database (International Prospective Register of Systematic Review) under registration number CRD42020210118.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tooth FracturesSpiral Cone-Beam Computed TomographyFractures, BoneHumansTooth RootSensitivity and SpecificityCone-Beam Computed Tomography

Stichwörter der Autor:innen

Cone-beam computed tomographyDiagnostic accuracyTooth fracturesVertical root fracture

Autor:innen und Institutionen

  • Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil.
  • Department of Stomatologic Sciences, School of Dentistry, Federal University of Goiás, Goiânia, GO, Brazil. brunno_santos@ufg.br.
  • University of Anápolis, Anápolis, GO, Brazil. brunno_santos@ufg.br.
  • University of Anápolis, Anápolis, GO, Brazil.

Zitieren

APA

de Lima, K. L., Silva, L. R., de Paiva Prado, T. B., Silva, M. A. G., de Freitas Silva, B. S., & Yamamoto-Silva, F. P. (2023). Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis. Clinical Oral Investigations. https://doi.org/10.1007/s00784-022-04797-z

Vancouver

de Lima KL, Silva LR, de Paiva Prado TB, Silva MAG, de Freitas Silva BS, Yamamoto-Silva FP. Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis. Clinical Oral Investigations. 2023. doi:10.1007/s00784-022-04797-z

BibTeX
@article{deLima2023,
  author = {de Lima, Kaique Leite and Silva, Lorena Rosa and de Paiva Prado, Thayse Bernardes and Silva, Maria Alves Garcia and de Freitas Silva, Brunno Santos and Yamamoto-Silva, Fernanda Paula},
  title = {Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis},
  journal = {Clinical Oral Investigations},
  year = {2023},
  doi = {10.1007/s00784-022-04797-z}
}
Kostenlos starten →