EUVIMEDΑνακαλύψτε το EUVIMED
Systematische ÜbersichtMetaanalyseVergleichsstudieÜbersichtsarbeit

Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance of Atrial Fibrillation Ablation: A Systematic Review and Meta‐Analysis of Procedural Safety and Efficacy

Afthab Salam Kanniyan, Omer Mohammed, Arshita Wadhwa, Sruthi Sai Purnima Koduri, Nimrah Fatima, Darshan Shivanne Gowda, Laura Marcela Romero-Acero, Michele Nanna, Shelby Kutty

Echocardiography · 2026-07 · 43 (7)

DOI: 10.1111/echo.70543 ↗

At a glance

Systematische Übersicht in Echocardiography, published online on 2026-07-02. Written by Afthab Salam Kanniyan and 8 co-authors. Institution: Government Medical College, Kozhikode, Kerala, India. Major MEDLINE topics: Atrial Fibrillation, Echocardiography, Transesophageal, Catheter Ablation, Ultrasonography, Interventional. 20 references.

ΠερίληψηSubjectsΒιβλιογραφικά στοιχείαCiteRelated studies

Abstract (original language)

Purpose

Transesophageal echocardiography (TEE) is the standard periprocedural imaging modality for atrial fibrillation (AF) catheter ablation but carries the burden of esophageal instrumentation, frequent deep sedation, and logistical constraints. Intracardiac echocardiography (ICE) is a growing alternative, yet comparative evidence had not been systematically synthesized. This systematic review and meta‐analysis compared ICE and TEE as periprocedural imaging strategies in adults undergoing AF catheter ablation, focusing on safety and procedural efficiency.

Methods

A search of PubMed, Embase, CENTRAL, and Web of Science identified six eligible studies (five cohort studies and one multicenter randomized controlled trial) enrolling 4760 participants (ICE n = 2616; TEE n = 2144). Peto odds ratios (OR) were used for dichotomous safety outcomes and mean differences (MD) with random‐effects models for continuous outcomes; certainty of evidence was graded using GRADE.

Results

ICE was not associated with significant differences in periprocedural complications, including cardiac tamponade (Peto OR 0.67, 95% CI 0.33–1.36), stroke/TIA/thromboembolism (0.81, 0.36–1.78), vascular complications (1.22, 0.70–2.13), or bleeding (0.50, 0.22–1.12). Total procedure duration did not differ (MD −7.11 min, 95% CI −18.82 to 4.61). ICE was associated with shorter fluoroscopy time (MD −4.17 min, −6.07 to −2.26), though this was attenuated after excluding studies with combined left atrial appendage occlusion. Certainty of evidence was low to very low; the absence of significant differences reflects imprecision rather than demonstrated equivalence and should be regarded as hypothesis‐generating.

Conclusion

Within these limitations, ICE may be a reasonable alternative to TEE in appropriately selected patients at centers with established ICE expertise. PROSPERO: CRD420251239269.

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationEchocardiography, TransesophagealCatheter AblationUltrasonography, InterventionalEchocardiographySurgery, Computer-AssistedHumansTreatment OutcomePostoperative Complications

Author keywords

atrial fibrillationcatheter ablationintracardiac echocardiographymeta‐analysisperiprocedural safetytransesophageal echocardiography

Authors and institutions

  • Government Medical College, Kozhikode, Kerala, India.
  • Shri Atal Bihari Vajpayee Medical College and Research Institute, Bangalore, India.
  • JSS Medical College, Mysore, India.
  • Ayaan Institute of Medical Sciences, Hyderabad, Telangana, India.
  • Hassan Institute of Medical Sciences, Hassan, Karnataka, India.
  • Cardiac Care and Vascular Medicine, Albert Einstein College of Medicine, New York City, New York, USA.

Cite

APA

Kanniyan, A. S., Mohammed, O., Wadhwa, A., Koduri, S. S. P., Fatima, N., Gowda, D. S., Romero-Acero, L. M., Nanna, M., & Kutty, S. (2026). Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance of Atrial Fibrillation Ablation: A Systematic Review and Meta‐Analysis of Procedural Safety and Efficacy. Echocardiography, 43(7). https://doi.org/10.1111/echo.70543

Vancouver

Kanniyan AS, Mohammed O, Wadhwa A, Koduri SSP, Fatima N, Gowda DS, et al. Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance of Atrial Fibrillation Ablation: A Systematic Review and Meta‐Analysis of Procedural Safety and Efficacy. Echocardiography. 2026;43(7). doi:10.1111/echo.70543

BibTeX
@article{Kanniyan2026,
  author = {Kanniyan, Afthab Salam and Mohammed, Omer and Wadhwa, Arshita and Koduri, Sruthi Sai Purnima and Fatima, Nimrah and Gowda, Darshan Shivanne and Romero-Acero, Laura Marcela and Nanna, Michele and Kutty, Shelby},
  title = {Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance of Atrial Fibrillation Ablation: A Systematic Review and Meta‐Analysis of Procedural Safety and Efficacy},
  journal = {Echocardiography},
  year = {2026},
  volume = {43},
  number = {7},
  doi = {10.1111/echo.70543}
}
Start for free →