Übersichtsarbeit in Echocardiography, 2025. Written by Dmitrij Kravchenko and 10 co-authors. Institution: Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Major MEDLINE topics: Tomography, X-Ray Computed, Heart Diseases, Heart. Cited 9 times so far (Crossref); 96 references. The full text is freely available (open access, CC BY 4.0).

РезюмеSubjectsБиблиографски данниCiteRelated studies

Abstract (original language)

It was only fitting that when computed tomography (CT) was celebrating its 50th birthday since its maiden scan in 1971, it was also entering into a new generation in 2021 with the Food and Drug Administration's approval of the first photon‐counting detector (PCD)‐CT. As non‐invasive cardiac imaging is evolving into an ever more important medical field, the introduction of this new technology promises a slew of improvements over energy‐integrating detector (EID)‐CTs, most importantly improved spatial resolution in the form of ultrahigh‐resolution (UHR) imaging, reduced radiation exposure, and routinely acquired spectral information. Spatial resolution has historically been a key hurdle for cardiac CT, especially for coronary imaging where structures in the realm of 2 mm need to be assessed. Initial reports on the use of PCD‐CT in cardiac imaging so far have been promising, but many questions ranging from standardized scan protocols to evidence‐based recommendations remain. The aim of this review is to discuss the currently available literature regarding the use of UHR PCD‐CT for cardiac imaging and explore if it has led to changes in guidelines or patient workflows.

Subjects

MeSH terms (MEDLINE)

Tomography, X-Ray ComputedHeart DiseasesHeartHumansPhotons

Author keywords

cardiac CTcoronary CTphoton‐counting detector CTultrahigh‐resolution

Authors and institutions

  • Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA.
  • Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany.
  • Quantitative Imaging Lab Bonn (QILaB), University Hospital Bonn, Bonn, Germany.
  • Department of Diagnostic and Interventional Radiology, Medical Centre, Faculty of Medicine, University of Freiburg, University of Freiburg, Freiburg im Breisgau, Germany.
  • Heart and Vascular Center, Semmelweis University, Budapest, Hungary.
  • Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit - Sant'Andrea University Hospital, Rome, Italy.

ORCID profiles: Dmitrij Kravchenko, Akos Varga-Szemes

Cite

APA

Kravchenko, D., Hagar, M. T., Vecsey-Nagy, M., Tremamunno, G., Szilveszter, B., Vattay, B., Zsarnóczay, E., Beke, S., Maurovich-Horvat, P., Emrich, T., & Varga-Szemes, A. (2025). Value of Ultrahigh‐Resolution Photon‐Counting Detector Computed Tomography in Cardiac Imaging. Echocardiography. https://doi.org/10.1111/echo.70100

Vancouver

Kravchenko D, Hagar MT, Vecsey-Nagy M, Tremamunno G, Szilveszter B, Vattay B, et al. Value of Ultrahigh‐Resolution Photon‐Counting Detector Computed Tomography in Cardiac Imaging. Echocardiography. 2025. doi:10.1111/echo.70100

BibTeX
@article{Kravchenko2025,
  author = {Kravchenko, Dmitrij and Hagar, Muhammad Taha and Vecsey-Nagy, Milan and Tremamunno, Giuseppe and Szilveszter, Bálint and Vattay, Borbála and Zsarnóczay, Emese and Beke, Sámuel and Maurovich-Horvat, Pál and Emrich, Tilman and Varga-Szemes, Akos},
  title = {Value of Ultrahigh‐Resolution Photon‐Counting Detector Computed Tomography in Cardiac Imaging},
  journal = {Echocardiography},
  year = {2025},
  doi = {10.1111/echo.70100}
}
Start for free →