Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system
British Journal of Radiology · 2025
DOI: 10.1093/bjr/tqaf069 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Radiology, 2025. Verfasst von Elisabeth Shanblatt und 7 weiteren Autor:innen. Beteiligte Einrichtung: Siemens Medical Solutions USA, Inc, Malvern, PA 19355, United States. Hauptthemen laut MEDLINE: Radiography, Dual-Energy Scanned Projection, Coronary Angiography, Computed Tomography Angiography, Tomography, X-Ray Computed. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Objectives
To assess quantitative and qualitative image characteristics in phantoms and patients using a simultaneous ultra-high resolution (UHR) and multi-energy (ME) dual-source cardiac scan mode in a photon counting detector (PCD) CT scanner.
Methods
UHR-ME cardiac scans were performed to determine the spatial resolution and multi-energy performance. UHR reconstructions were completed to measure transverse and axial spatial resolution in terms of modulation transfer function (MTF) and slice sensitivity profile (SSP). Virtual monoenergetic images (VMIs), virtual non-contrast (VNC) images, and iodine concentration images were created using moderately sharp reconstruction kernels to assess ME performance. With IRB approval, coronary CT angiograms were acquired in 19 patients using the UHR-ME mode, from which iodine contrast-to-noise ratio (CNR) was measured. Various ME post-processing tasks were performed to show the utility of the spectral capabilities.
Results
VMIs showed a mean CT number error of 6.0%, while iodine accuracy was 0.71 mg/cc (root-mean-square-error). Spatial resolution matched well with a standard UHR mode. Patient images showed a trend of higher CNR at lower keV, while higher keV images showed decreased calcium blooming. ME techniques to separate iodine and calcium were used successfully.
Conclusions
The combination of UHR-ME cardiac mode retains UHR image quality while providing flexibility for ME post-processing. Advances in knowledge Cardiac UHR-ME PCD-CT scanning offers simultaneous UHR and ME imaging without loss of spatial or temporal resolution or quantitative accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Siemens Medical Solutions USA, Inc, Malvern, PA 19355, United States.
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States.
- Siemens Healthineers, Forchheim, 91301, Germany.
- Institute of Radiology, Friedrich-Alexander University, Erlangen, 91054, Germany.
ORCID-Profile: Cynthia H McCollough, Shuai Leng
Förderung
- NIBIB NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Shanblatt, E., Rajendran, K., Swicklik, J. R., Allmendinger, T., Schmidt, B., Flohr, T., McCollough, C. H., & Leng, S. (2025). Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system. British Journal of Radiology. https://doi.org/10.1093/bjr/tqaf069
Vancouver
Shanblatt E, Rajendran K, Swicklik JR, Allmendinger T, Schmidt B, Flohr T, et al. Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system. British Journal of Radiology. 2025. doi:10.1093/bjr/tqaf069
BibTeX
@article{Shanblatt2025,
author = {Shanblatt, Elisabeth and Rajendran, Kishore and Swicklik, Joseph R and Allmendinger, Thomas and Schmidt, Bernhard and Flohr, Thomas and McCollough, Cynthia H and Leng, Shuai},
title = {Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system},
journal = {British Journal of Radiology},
year = {2025},
doi = {10.1093/bjr/tqaf069}
}
EUVIMED