EUVIMEDEUVIMED entdecken
Vergleichsstudie

Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination

Ginevra Fioretti, Alice Tolomei iD, Piera Ciaramella, Antonio Lio, Ernesto Cristiano, Giulio Cacioli, Federica Tempestini, Federico Ranocchi, Viviana Maestrini iD, Amedeo Pergolini

Echocardiography · 2024

DOI: 10.1111/echo.70040 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Echocardiography, 2024. Verfasst von Ginevra Fioretti und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery and Heart Transplantation, San Camillo Forlanini, Rome, Italy. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Mitral Valve Insufficiency, Echocardiography, Transesophageal, Software. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Preoperative echocardiographic assessment is critical for patients with severe degenerative mitral regurgitation to ensure personalized surgical mitral valve repair. This study aimed to compare the diagnostic accuracy of three‐dimensional transthoracic echocardiography (3D TTE) and three‐dimensional transesophageal echocardiography (3D TEE) in identifying valvular lesions, using surgical findings as the reference. Additionally, we evaluated whether annular dimensional parameters derived from TTE and TEE, using dedicated 3D software, could confirm whether 3D TTE alone offers a comprehensive preoperative evaluation.

Methods

We enrolled 60 patients with severe organic mitral regurgitation scheduled for surgical valve repair. Each patient underwent preoperative 3D TTE, intraoperative 3D TEE prior to surgery, followed by annuloplasty. Mitral valve reconstructions from both TTE and TEE were compared, and dedicated 3D software (EchoPAC GE‐Health‐Care Software 3D‐auto‐MVQ) was employed to reconstruct annular geometries from both methods.

Results

Both 3D TTE and 3D TEE demonstrated comparable accuracy in identifying diseased scallops (overall accuracy: 3D TTE 91.8%, 3D TEE 98.1%, p > 0.05). However, 3D TTE was inferior to 3D TEE in identifying multiple chordal ruptures (accuracy: 3D TTE 80%, 3D TEE 100%). Quantitative analysis of the mitral annulus revealed that 3D TTE and 3D TEE yielded overlapping results for static parameters ( p > 0.05), whereas dynamic parameters differed significantly ( p < 0.05).

Conclusions

In the selected population, 3D TTE demonstrated diagnostic accuracy comparable to transesophageal echocardiography in identifying mitral valve lesions. Furthermore, with the use of dedicated 3D software, TTE alone may provide a comprehensive and noninvasive preoperative evaluation, particularly for static annular parameters. Further studies are warranted to corroborate these findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, Three-DimensionalMitral Valve InsufficiencyEchocardiography, TransesophagealSoftwareMitral ValveHumansFemaleMaleMiddle AgedReproducibility of ResultsAged

Stichwörter der Autor:innen

3D softwareannuloplastydegenerative mitral valve diseasethree‐dimensional echocardiography

Autor:innen und Institutionen

  • Department of Cardiac Surgery and Heart Transplantation, San Camillo Forlanini, Rome, Italy.
  • Department of Clinical, Internal Medicine, Anesthesiology and Cardiovascular Sciences, Sapienza University of Rome, Rome, Italy.
  • Cardiac Electrophysiology Complex Operational Unit, Humanitas Gavazzeni-Castelli, Bergamo, Italy.

ORCID-Profile: Alice Tolomei, Viviana Maestrini

Zitieren

APA

Fioretti, G., Tolomei, A., Ciaramella, P., Lio, A., Cristiano, E., Cacioli, G., Tempestini, F., Ranocchi, F., Maestrini, V., & Pergolini, A. (2024). Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination. Echocardiography. https://doi.org/10.1111/echo.70040

Vancouver

Fioretti G, Tolomei A, Ciaramella P, Lio A, Cristiano E, Cacioli G, et al. Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination. Echocardiography. 2024. doi:10.1111/echo.70040

BibTeX
@article{Fioretti2024,
  author = {Fioretti, Ginevra and Tolomei, Alice and Ciaramella, Piera and Lio, Antonio and Cristiano, Ernesto and Cacioli, Giulio and Tempestini, Federica and Ranocchi, Federico and Maestrini, Viviana and Pergolini, Amedeo},
  title = {Study of Degenerative Mitral Regurgitation Using Three‐Dimensional Echocardiography and EchoPAC GE Health Care Software 4D Auto MVQ: Comparison Between Transthoracic and Transesophageal Examination},
  journal = {Echocardiography},
  year = {2024},
  doi = {10.1111/echo.70040}
}
Kostenlos starten →