EUVIMEDEUVIMED entdecken
Vergleichsstudie

Optimizing Device Selection in Percutaneous Paravalvular Leak Closure: A Comparative Study of Different Transthoracic and Transesophageal Echocardiographic Techniques

Meltem Tekin iD, Gamze Babur Güler, Mehmet Çiçek, İbrahim Halil Tanboğa, Piotr Pysz, Arda Güler, Ali Rıza Demir, Yusuf Efe, Sezgin Atmaca, Dilara Pay iD, Ali Kemal Kalkan, Mehmet Ertürk

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31448 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Meltem Tekin und 11 weiteren Autor:innen. Beteiligte Einrichtung: TC Saglik Bakanligi Mehmet Akif Ersoy Gogus Kalp ve Damar Cerrahisi Egitim ve Arastirma Hastanesi, Istanbul, Turkey. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Cardiac Catheterization, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Clinically significant paravalvular leak (PVL) may complicate both surgical and transcatheter valve implantation. Percutaneous PVL closure (PPVLC) is becoming an increasingly attractive alternative to redo surgery, with demonstrated lower mortality and morbidity rates. Echocardiographic techniques are crucial for accurate diagnosis, defect sizing, and determining the appropriate size of the sealing devices.

Aims

There is no consensus on the optimal imaging modality for PVLs. We aimed to compare transthoracic and transesophageal echocardiographic measurements to accurately determine defect size and estimate device size.

Methods

We reviewed hospital records to identify patients diagnosed with moderate to severe and severe PVL from 2018 to 2024. A total of 81 patients who underwent PPVLC were evaluated. Eight of these patients were excluded due to unsuccessful PPVLC, leaving 73 patients who were successfully treated. The defect size for all patients was evaluated using 2D transthoracic echocardiography (TTE), 2D transesophageal echocardiography (TEE), direct 3D TEE cropped volume rendering vena contracta (VC) measurement, and 3D TEE multiplanar reconstruction (3D TEE MPR).

Results

Among the 73 patients, 42 underwent aortic PPVLC and 31 underwent mitral PPVLC. Proportional odds logistic regression analysis identified 3D TEE MPR measurement as the strongest predictor of device size accuracy, both overall and within the aortic/mitral subgroups. In the mitral subgroup, the predictive power of direct 3D TEE cropped volume rendering VC measurement and 3D TEE MPR measurement were similar. Furthermore, a cut‐off value of 7 mm was identified for hemodynamically significant jets as measured by 3D methods.

Conclusion

Our findings suggest that using 3D TEE MPR significantly improves the accuracy of device size selection in both mitral and aortic PVL. Additionally, direct 3D TEE cropped volume rendering VC measurement can serve as a viable alternative for patients with mitral PVL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, TransesophagealCardiac CatheterizationHeart Valve ProsthesisHeart Valve Prosthesis ImplantationMitral ValveMitral Valve InsufficiencyAortic ValveAortic Valve InsufficiencyEchocardiography, Three-DimensionalEchocardiographyHumansMaleFemalePredictive Value of TestsAgedTreatment OutcomeRetrospective StudiesProsthesis DesignMiddle AgedAged, 80 and overRisk FactorsReproducibility of Results

Autor:innen und Institutionen

  • TC Saglik Bakanligi Mehmet Akif Ersoy Gogus Kalp ve Damar Cerrahisi Egitim ve Arastirma Hastanesi, Istanbul, Turkey.
  • Hisar Hospital Intercontinental, Istanbul, Turkey.
  • Uniwersytet Slaski w Katowicach, Katowice, Poland.

ORCID-Profile: Meltem Tekin, Dilara Pay

Zitieren

APA

Tekin, M., Güler, G. B., Çiçek, M., Tanboğa, İ. H., Pysz, P., Güler, A., Demir, A. R., Efe, Y., Atmaca, S., Pay, D., Kalkan, A. K., & Ertürk, M. (2025). Optimizing Device Selection in Percutaneous Paravalvular Leak Closure: A Comparative Study of Different Transthoracic and Transesophageal Echocardiographic Techniques. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31448

Vancouver

Tekin M, Güler GB, Çiçek M, Tanboğa İH, Pysz P, Güler A, et al. Optimizing Device Selection in Percutaneous Paravalvular Leak Closure: A Comparative Study of Different Transthoracic and Transesophageal Echocardiographic Techniques. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31448

BibTeX
@article{Tekin2025,
  author = {Tekin, Meltem and Güler, Gamze Babur and Çiçek, Mehmet and Tanboğa, İbrahim Halil and Pysz, Piotr and Güler, Arda and Demir, Ali Rıza and Efe, Yusuf and Atmaca, Sezgin and Pay, Dilara and Kalkan, Ali Kemal and Ertürk, Mehmet},
  title = {Optimizing Device Selection in Percutaneous Paravalvular Leak Closure: A Comparative Study of Different Transthoracic and Transesophageal Echocardiographic Techniques},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31448}
}
Kostenlos starten →