EUVIMEDOpdag EUVIMED
ÜbersichtsarbeitOpen access · CC BY 4.0

The Role of 2, 4, and 5‐dimensional Cardiac Flow MRI for Evaluation of Valvulopathies: A Literature Review

Sara Fässler iD, Mariana B L Falcão iD, Stefano F de Marchi iD, Christopher W Roy iD, Tobias Rutz iD

Echocardiography · 2024

DOI: 10.1111/echo.70005 ↗

At a glance

Übersichtsarbeit in Echocardiography, 2024. Written by Sara Fässler and 4 co-authors. Institution: Service of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland. Major MEDLINE topics: Heart Valve Diseases. Cited 2 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Aim

Two‐dimensional phase‐contrast magnetic resonance imaging (2D flow MRI) and its multidimensional alternatives, 4D and 5D flow MRI, measure blood flow in the heart and great vessels. While 2D flow MRI is the standard technique, it has limitations regarding need for precise image plane prescribing and long scan time. In contrast, 4D and 5D flow MRI acquire 3D volumes, enabling retrospective assessment of all vessels. This review evaluates these three techniques for quantification of blood flow of the aortic and pulmonary valves in congenital heart disease.

Methods

A systematic literature search was conducted in August 2024 using the PUBMED database, including articles comparing 2D, 4D, and 5D flow MRI.

Results

Fifteen articles comparing 2D and 4D, one comparing 2D and 5D and three articles comparing 4D and 5D flow MRI were included. No study compared all three techniques. 2D, 4D and 5D flow MRI demonstrated a good agreement for flow quantification. 4D flow MRI, however, tends to present a better accuracy and internal consistency than 2D flow MRI for determination of peak velocities and flow in stenotic lesions, particularly when comparing velocities to echocardiography. 4D and 5D flow MRI are associated with shorter scan times than 2D flow MRI.

Conclusions

4D and 5D flow MRI appear to offer promising alternatives to 2D flow MRI with the advantage of reduced scan times. Larger and prospective studies including echocardiography are needed to evaluate the potential of 4D and 5D to replace 2D flow MRI for flow quantification and peak velocity determination.

Subjects

MeSH terms (MEDLINE)

Heart Valve DiseasesHumansBlood Flow VelocityHeart Defects, CongenitalMagnetic Resonance ImagingAortic ValvePulmonary ValveImaging, Three-Dimensional

Author keywords

2D cardiac flow MRI4D cardiac flow MRI5D cardiac flow MRIcardiac magnetic resonance imaging

Authors and institutions

  • Service of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Department of Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Service of Cardiology, Bern University Hospital and University of Bern, Bern, Switzerland.

ORCID profiles: Sara Fässler, Mariana B L Falcão, Stefano F de Marchi, Christopher W Roy, Tobias Rutz

Cite

APA

Fässler, S., Falcão, M. B. L., de Marchi, S. F., Roy, C. W., & Rutz, T. (2024). The Role of 2, 4, and 5‐dimensional Cardiac Flow MRI for Evaluation of Valvulopathies: A Literature Review. Echocardiography. https://doi.org/10.1111/echo.70005

Vancouver

Fässler S, Falcão MBL, de Marchi SF, Roy CW, Rutz T. The Role of 2, 4, and 5‐dimensional Cardiac Flow MRI for Evaluation of Valvulopathies: A Literature Review. Echocardiography. 2024. doi:10.1111/echo.70005

BibTeX
@article{Fssler2024,
  author = {Fässler, Sara and Falcão, Mariana B L and de Marchi, Stefano F and Roy, Christopher W and Rutz, Tobias},
  title = {The Role of 2, 4, and 5‐dimensional Cardiac Flow MRI for Evaluation of Valvulopathies: A Literature Review},
  journal = {Echocardiography},
  year = {2024},
  doi = {10.1111/echo.70005}
}
Start for free →