Flow evaluation software for four-dimensional flow MRI: a reliability and validation study

Barbara Elisabeth Ursula Burkhardt, Christian Johannes Kellenberger, Fraser Maurice Callaghan, Emanuela Regina Valsangiacomo Buechel, Julia Geiger

La radiologia medica · 2023

DOI: 10.1007/s11547-023-01697-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift La radiologia medica, 2023. Verfasst von Barbara Elisabeth Ursula Burkhardt und 4 weiteren Autor:innen. Beteiligte Einrichtung: Paediatric Cardiology, Pediatric Heart Center, Department of Surgery, University Children's Hospital Zürich, Steinwiesstrasse 75, 8032, Zurich, Switz…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Heart Defects, Congenital. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Zürich, University of Zurich.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC). Material and methods 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.6–52 years) were acquired at 1.5 T. Net flow volumes in the ascending aorta, the main, right, and left pulmonary arteries were measured using four different postprocessing software applications and compared to offset-corrected 2D PC data. Reliability of 4D flow postprocessing software was assessed by Bland–Altman analysis and intraclass correlation coefficient (ICC). Linear regression of internal flow controls was calculated. Interobserver reproducibility was evaluated in 25 patients.

Results

Correlation and agreement of flow volumes were very good for all software compared to 2D PC (ICC ≥ 0.94; bias ≤ 5%). Internal controls were excellent for 2D PC ( r ≥ 0.95, p < 0.001) and 4D flow ( r ≥ 0.94, p < 0.001) without significant difference of correlation coefficients between methods. Interobserver reliability was good for all vendors (ICC ≥ 0.94, agreement bias < 8%).

Conclusion

Haemodynamic information from 4D flow in the large thoracic arteries assessed by four commercially available postprocessing applications matches routinely performed 2D PC values. Therefore, we consider 4D flow MRI-derived data ready for clinical use in patients with CHD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingHeart Defects, CongenitalHumansInfantChild, PreschoolChildAdolescentYoung AdultAdultMiddle AgedReproducibility of ResultsBlood Flow VelocityAortaSoftwareImaging, Three-Dimensional

Stichwörter der Autor:innen

4D flow MRICardiac magnetic resonanceCongenital heart diseaseFlow quantificationHaemodynamicsPhase-contrast magnetic resonance imaging

Autor:innen und Institutionen

  • Paediatric Cardiology, Pediatric Heart Center, Department of Surgery, University Children's Hospital Zürich, Steinwiesstrasse 75, 8032, Zurich, Switzerland. barbara.burkhardt@kispi.uzh.ch.
  • Children's Research Center, University Children's Hospital Zürich, Zurich, Switzerland. barbara.burkhardt@kispi.uzh.ch.
  • Department of Diagnostic Imaging, University Children's Hospital Zürich, Zurich, Switzerland.
  • Children's Research Center, University Children's Hospital Zürich, Zurich, Switzerland.
  • Paediatric Cardiology, Pediatric Heart Center, Department of Surgery, University Children's Hospital Zürich, Steinwiesstrasse 75, 8032, Zurich, Switzerland.

Förderung

  • Universität Zürich
  • University of Zurich

Zitieren

APA

Burkhardt, B. E. U., Kellenberger, C. J., Callaghan, F. M., Valsangiacomo Buechel, E. R., & Geiger, J. (2023). Flow evaluation software for four-dimensional flow MRI: a reliability and validation study. La radiologia medica. https://doi.org/10.1007/s11547-023-01697-4

Vancouver

Burkhardt BEU, Kellenberger CJ, Callaghan FM, Valsangiacomo Buechel ER, Geiger J. Flow evaluation software for four-dimensional flow MRI: a reliability and validation study. La radiologia medica. 2023. doi:10.1007/s11547-023-01697-4

BibTeX
@article{Burkhardt2023,
  author = {Burkhardt, Barbara Elisabeth Ursula and Kellenberger, Christian Johannes and Callaghan, Fraser Maurice and Valsangiacomo Buechel, Emanuela Regina and Geiger, Julia},
  title = {Flow evaluation software for four-dimensional flow MRI: a reliability and validation study},
  journal = {La radiologia medica},
  year = {2023},
  doi = {10.1007/s11547-023-01697-4}
}
Kostenlos starten →