Echocardiographic assessment of pediatric heart transplantation: A single‐center experience in China
Echocardiography · 2024
DOI: 10.1111/echo.15771 ↗Kurz gefasst
Fachartikel in der Zeitschrift Echocardiography, 2024. Verfasst von Yuji Xie und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Heart Transplantation, Ventricular Dysfunction, Right. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Shenzhen Science and Technology, Key Research and Development Program of Hubei, National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Pediatric heart transplant (HT) has become the standard of care for end‐stage heart failure in children worldwide. Serial echocardiographic evaluations of graft anatomy and function during follow‐up are crucial for post‐HT management. However, evolution of cardiac structure and function after pediatric HT has not been well described, especially during first year post‐HT. This study aimed to characterize the evolution of cardiac structure and function after pediatric HT and investigate the correlation between biventricular function with adverse clinical outcomes.
Methods
A single‐center retrospective study of echocardiographic data obtained among 99 pediatric HT patients was conducted. Comprehensive echocardiographic examination was performed in all patients at 1‐, 3‐, 6‐, 9‐ and 12‐months post‐HT. We obtained structural, functional and hemodynamic parameters from both left‐ and right‐side heart, such as left ventricular stroke volume (LVSV), left ventricular ejection fraction (LVEF), right ventricular fractional area change (RVFAC), etc. The cardiac evolution of pediatric HT patients during first post‐HT year was described and compared between different time points. We also explored the correlation between cardiac function and major adverse transplant events (MATEs).
Results
1) Evolution of left heart parameters: left atrial length, mitral E velocity, E/A ratio, LVSV and LVEF significantly increased while mitral A velocity significantly decreased over the first year after HT ( P < .05). Compared with 1 month after HT, interventricular septum (IVS) and left ventricular posterior wall (LVPW) decreased at 3 months but increased afterwards. (2) Evolution of right heart parameters: right ventricular base diameter and mid‐diameter; right ventricular length diameter, tricuspid E velocity, E/A ratio, tricuspid annular velocity e’ at free wall, and RVFAC increased, while tricuspid A velocity decreased over the first year after HT ( P < .05). (3) Univariate logistic regression model suggests that biventricular function parameters at 1‐year post‐HT (LVEF, RVFAC, tricuspid annular plane systolic excursion and tricuspid lateral annular systolic velocity) were associated with MATEs.
Conclusion
Gradual improvement of LV and RV function was seen in pediatric HT patients within the first year. Biventricular function parameters associated with MATEs. The results of this study pave way for designing larger and longer follow‐up of this population, potentially aiming at using multiparameter echocardiographic prediction of adverse events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan, China.
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China.
- Shenzhen Huazhong University of Science and Technology Research Institute, Shenzhen, China.
ORCID-Profile: Yun Yang, Mingxing Xie, Li Zhang
Förderung
- Shenzhen Science and Technology
- Key Research and Development Program of Hubei
- National Natural Science Foundation of China
Zitieren
APA
Xie, Y., Sun, W., Zhu, S., Zhang, L., Zhang, Y., Zhang, Y., Yang, Y., Wang, L., Zhao, Y., Xiao, S., Li, Y., Xie, M., & Zhang, L. (2024). Echocardiographic assessment of pediatric heart transplantation: A single‐center experience in China. Echocardiography. https://doi.org/10.1111/echo.15771
Vancouver
Xie Y, Sun W, Zhu S, Zhang L, Zhang Y, Zhang Y, et al. Echocardiographic assessment of pediatric heart transplantation: A single‐center experience in China. Echocardiography. 2024. doi:10.1111/echo.15771
BibTeX
@article{Xie2024,
author = {Xie, Yuji and Sun, Wei and Zhu, Shuangshuang and Zhang, Linyue and Zhang, Yanting and Zhang, Yiwei and Yang, Yun and Wang, Lufang and Zhao, Yang and Xiao, Sushan and Li, Yuman and Xie, Mingxing and Zhang, Li},
title = {Echocardiographic assessment of pediatric heart transplantation: A single‐center experience in China},
journal = {Echocardiography},
year = {2024},
doi = {10.1111/echo.15771}
}
EUVIMED