EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Is cardiopulmonary transit time (CPTT) measured by using dynamic rubidium cardiac PET/CT a predictor for cardiac function?

Lena C Seige, Boya Zhang, Jakob Heimer, Noel Spielhofer, Cristina Popescu, Karsten Murray, Christian La Fougère, Irene A Burger, Alexander W Sauter

The International Journal of Cardiovascular Imaging · 2025

DOI: 10.1007/s10554-025-03346-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Cardiovascular Imaging, 2025. Verfasst von Lena C Seige und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Cantonal Hospital Baden, Partner Hospital for Research and Teaching of the Medical Faculty of the University of Zuric…. Hauptthemen laut MEDLINE: Rubidium Radioisotopes, Positron Emission Tomography Computed Tomography, Ventricular Function, Left, Myocardial Perfusion Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Tübingen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiopulmonary transit time (CPTT) represents the time needed for the circulation of blood from the right to the left ventricle. This parameter can be measured during dynamic acquisition of rubidium ([ 82 Rb]) cardiac PET/CT. To further characterize this marker, we wanted to assess the association between CPTT and parameters of cardiac function derived from echocardiography. Retrospective single center analysis of patients referred to [ 82 Rb]RbCl-PET/CT with rest/stress protocol on an integrated hybrid PET/CT system (Biograph mCT, Siemens Healthineers, Erlangen, Germany) and echocardiography within 100 days. After intravenous injection of 7.5 MBq/kg [ 82 Rb]RbCl dynamic scans with initially 12 × 10 s frames were started. For data analysis a volume of interest (VOI) was drawn in the left and right ventricle using dedicated software. The difference between the peak time for the two time activity curves (TAC) was extracted as CPTT and normalized for heart rate (NCPTT). Associations between NCPTT and echo parameters such as left ventricular ejection fraction (EF Echo ) were analyzed using linear regression models. 44 patients (sex: 28 male, 16 female) were enrolled with a time difference between PET and echocardiography of 19.65 ± 23.3 days. 9 patients had a rest CPTT of 0 s, 32 patients 10 s and 3 patients 20 s. The association between EF Echo and NCPTT revealed a significant negative correlation (beta = -0.77; CI: -1.32, -0.22; p = 0.007). Given this association, univariate predictive models for EF Echo were applied. Root mean square error was 6.83% for the EF PET , and 6.0% for NCPTT, which indicates a slightly higher predictive performance for the NCPTT model with a lower error. Pulmonary transit time can be estimated with [ 82 Rb]RbCl-PET/CT, with a high positive association to rest EF Echo . However, smaller time frames than 10 s are needed, for more accurate estimation of cardiac function. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rubidium RadioisotopesPositron Emission Tomography Computed TomographyVentricular Function, LeftMyocardial Perfusion ImagingRadiopharmaceuticalsVentricular Function, RightCoronary CirculationHeart DiseasesHumansMaleFemalePredictive Value of TestsRetrospective StudiesMiddle AgedAgedTime FactorsStroke VolumeReproducibility of ResultsAdultEchocardiography

Stichwörter der Autor:innen

EchocardiographyMyocardial perfusion imagingPositron Emission Tomography Computed TomographyPulmonary transit TimeRubidium-82

Substanzen

Rubidium RadioisotopesRadiopharmaceuticalsRubidium-82

Autor:innen und Institutionen

  • Department of Nuclear Medicine, Cantonal Hospital Baden, Partner Hospital for Research and Teaching of the Medical Faculty of the University of Zurich, Baden, 5404, Switzerland.
  • University Hospital Basel, University of Basel, Basel, 4031, Switzerland.
  • Department of Mathematics, Seminar for Statistics, ETH Zurich, Zurich, 8092, Switzerland.
  • Department of Cardiology, Cantonal Hospital Baden, Baden, Baden, 5404, Switzerland.
  • Department of Nuclear Medicine and Clinical Molecular Imaging, University Hospital Tuebingen, 72074, Tuebingen, Germany.
  • Department of Nuclear Medicine, University Hospital Zurich, University of Zurich, Zurich, 8006, Switzerland.

Förderung

  • Universitätsklinikum Tübingen

Zitieren

APA

Seige, L. C., Zhang, B., Heimer, J., Spielhofer, N., Popescu, C., Murray, K., La Fougère, C., Burger, I. A., & Sauter, A. W. (2025). Is cardiopulmonary transit time (CPTT) measured by using dynamic rubidium cardiac PET/CT a predictor for cardiac function?. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-025-03346-5

Vancouver

Seige LC, Zhang B, Heimer J, Spielhofer N, Popescu C, Murray K, et al. Is cardiopulmonary transit time (CPTT) measured by using dynamic rubidium cardiac PET/CT a predictor for cardiac function?. The International Journal of Cardiovascular Imaging. 2025. doi:10.1007/s10554-025-03346-5

BibTeX
@article{Seige2025,
  author = {Seige, Lena C and Zhang, Boya and Heimer, Jakob and Spielhofer, Noel and Popescu, Cristina and Murray, Karsten and La Fougère, Christian and Burger, Irene A and Sauter, Alexander W},
  title = {Is cardiopulmonary transit time (CPTT) measured by using dynamic rubidium cardiac PET/CT a predictor for cardiac function?},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2025},
  doi = {10.1007/s10554-025-03346-5}
}
Kostenlos starten →