Left atrial strain brings new insights for evaluating early diastolic dysfunction in patients with well‐functioning bicuspid aortic valve
Echocardiography · 2023-11 · 40 (11) · 1243-1250
DOI: 10.1111/echo.15704 ↗At a glance
Journal article in Echocardiography, published online on 2023-10-17. Written by Yuting Tan and 11 co-authors. Institution: Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Major MEDLINE topics: Bicuspid Aortic Valve Disease, Heart Valve Diseases, Atrial Fibrillation, Vascular Stiffness. Cited 3 times so far (Crossref); 24 references. Funded by: National Natural Science Foundation of China.
Abstract (original language)
Background
Left atrial reservoir strain (LARS) is an early sensor of left ventricular (LV) diastolic dysfunction. Still, the clinical implications of LARS in patients with well‐functioning bicuspid aortic valve (BAV) remain unknown. Materials The study recruited 103 patients with well‐functioning BAV and 50 controls with tricuspid aortic valves. LARS, LV global longitudinal strain (LVGLS) and aortic elasticity indices (aortic strain, aortic distensibility and stiffness index) were acquired. This study aimed to analyze the changes of LARS and further explore the influential factors of LARS in patients with well‐functioning BAV.
Results
Patients with BAV had lower LARS (34.17 ± 4.85 vs. 44.72 ± 6.06 %, P < .001) and LVGLS (20.53 ± 1.28 vs. 22.30 ± .62 %, P < .001), and abnormal aortic elasticity indices (aortic strain:7.14 ± 1.57 vs. 10.99 ± 1.03 %, aortic distensibility: 5.82 ± 1.50 vs. 8.98 ± 2.42 (10 −6 cm 2 dyne −1 ), and stiffness index: 6.30 ± 2.30 vs. 3.92 ± .98, all P < .05) compared with controls. LARS was associated with LVGLS ( r = .799), interventricular septum index ( r = −.232), lateral e' ( r = .290), septal e' ( r = .308), E/e' ratio ( r = −.392), aortic strain ( r = .829), aortic distensibility ( r = .361), and stiffness index ( r = −.724) (all P < .05). LVGLS, aortic strain and E/e' ratio were independent influencers of LARS in the multifactorial analysis model (all P < .05).
Conclusion
In patients with well‐functioning BAV, decreased LARS may provide evidence of subclinical LV diastolic function impairment. LARS may be helpful for clinical risk stratification in such a population.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Ultrasound, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan, China.
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan, China.
ORCID profiles: Mingxing Xie, Jing Wang
Funding
- National Natural Science Foundation of China
Cite
APA
Tan, Y., Deng, W., Liu, T., Huang, L., Zhang, R., Zhang, Y., Fu, Y., Fang, L., Li, Y., Zhang, L., Xie, M., & Wang, J. (2023). Left atrial strain brings new insights for evaluating early diastolic dysfunction in patients with well‐functioning bicuspid aortic valve. Echocardiography, 40(11), 1243-1250. https://doi.org/10.1111/echo.15704
Vancouver
Tan Y, Deng W, Liu T, Huang L, Zhang R, Zhang Y, et al. Left atrial strain brings new insights for evaluating early diastolic dysfunction in patients with well‐functioning bicuspid aortic valve. Echocardiography. 2023;40(11):1243-1250. doi:10.1111/echo.15704
BibTeX
@article{Tan2023,
author = {Tan, Yuting and Deng, Wenhui and Liu, Tianshu and Huang, Lei and Zhang, Ruize and Zhang, Yichan and Fu, Yanan and Fang, Lingyun and Li, Yuman and Zhang, Li and Xie, Mingxing and Wang, Jing},
title = {Left atrial strain brings new insights for evaluating early diastolic dysfunction in patients with well‐functioning bicuspid aortic valve},
journal = {Echocardiography},
year = {2023},
volume = {40},
number = {11},
pages = {1243--1250},
doi = {10.1111/echo.15704}
}
EUVIMED