Age is superior to aortopathy phenotype as a predictor of aortic mechanics in patients with bicuspid valve

Matthew A Thompson, Benjamin Kramer, Samar A Tarraf, Emily Vianna, Callan Gillespie, Emidio Germano, Brett Gentle, Frank Cikach, Ashley M Lowry, Amol Pande, Eugene Blackstone, Jennifer Hargrave und 3 weitere

The Journal of Thoracic and Cardiovascular Surgery · 2025

DOI: 10.1016/j.jtcvs.2023.12.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2025. Verfasst von Matthew A Thompson und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Aortic Center, Heart, Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, Ohio. Hauptthemen laut MEDLINE: Bicuspid Aortic Valve Disease, Aortic Valve, Aorta, Heart Valve Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Bicuspid aortic valve (BAV) aortopathy is defined by 3 phenotypes-root, ascending, and diffuse-based on region of maximal aortic dilation. We sought to determine the association between aortic mechanical behavior and aortopathy phenotype versus other clinical variables. METHODS: From August 1, 2016, to March 1, 2023, 375 aortic specimens were collected from 105 patients undergoing elective ascending aortic aneurysm repair for BAV aortopathy. Planar biaxial data (191 specimens) informed constitutive descriptors of the arterial wall that were combined with in vivo geometry and hemodynamics to predict stiffness, stress, and energy density under physiologic loads. Uniaxial testing (184 specimens) evaluated failure stretch and failure Cauchy stress. Boosting regression was implemented to model the association between clinical variables and mechanical metrics. RESULTS: There were no significant differences in mechanical metrics between the root phenotype (N = 33, 31%) and ascending/diffuse phenotypes (N = 72, 69%). Biaxial testing demonstrated older age was associated with increased circumferential stiffness, decreased stress, and decreased energy density. On uniaxial testing, longitudinally versus circumferentially oriented specimens failed at significantly lower Cauchy stress (50th [15th, 85th percentiles]: 1.0 [0.7, 1.6] MPa vs 1.9 [1.3, 3.1] MPa; P < .001). Age was associated with decreased failure stretch and stress. Elongated ascending aortas were also associated with decreased failure stress. CONCLUSIONS: Aortic mechanical function under physiologic and failure conditions in BAV aortopathy is robustly associated with age and poorly associated with aortopathy phenotype. Data suggesting that the root phenotype of BAV aortopathy portends worse outcomes are unlikely to be related to aberrant, phenotype-specific tissue mechanics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bicuspid Aortic Valve DiseaseAortic ValveAortaHeart Valve DiseasesAortic AneurysmHumansMaleFemaleMiddle AgedPhenotypeAgedAge FactorsAdultVascular StiffnessBiomechanical PhenomenaHemodynamicsStress, Mechanical

Stichwörter der Autor:innen

aortic rootaortopathybicuspid aortic valvebiomechanicsstiffness

Autor:innen und Institutionen

  • Department of Thoracic and Cardiovascular Surgery, Aortic Center, Heart, Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, Ohio.
  • Department of Bioengineering, College of Engineering, Northeastern University, Boston, Mass.
  • Department of Biomedical Engineering, BioRobotics and Mechanical Testing Core, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio.
  • Department of Cardiothoracic Anesthesiology, Cleveland Clinic, Cleveland, Ohio.
  • Department of Quantitative Health Sciences, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio.
  • Department of Thoracic and Cardiovascular Surgery, Aortic Center, Heart, Vascular & Thoracic Institute, Cleveland Clinic, Cleveland, Ohio; Department of Quantitative Health Sciences, Lerner Research Institute, Cleveland…

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Thompson, M. A., Kramer, B., Tarraf, S. A., Vianna, E., Gillespie, C., Germano, E., Gentle, B., Cikach, F., Lowry, A. M., Pande, A., Blackstone, E., Hargrave, J., Colbrunn, R., Bellini, C., & Roselli, E. E. (2025). Age is superior to aortopathy phenotype as a predictor of aortic mechanics in patients with bicuspid valve. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2023.12.018

Vancouver

Thompson MA, Kramer B, Tarraf SA, Vianna E, Gillespie C, Germano E, et al. Age is superior to aortopathy phenotype as a predictor of aortic mechanics in patients with bicuspid valve. The Journal of Thoracic and Cardiovascular Surgery. 2025. doi:10.1016/j.jtcvs.2023.12.018

BibTeX
@article{Thompson2025,
  author = {Thompson, Matthew A and Kramer, Benjamin and Tarraf, Samar A and Vianna, Emily and Gillespie, Callan and Germano, Emidio and Gentle, Brett and Cikach, Frank and Lowry, Ashley M and Pande, Amol and Blackstone, Eugene and Hargrave, Jennifer and Colbrunn, Robb and Bellini, Chiara and Roselli, Eric E},
  title = {Age is superior to aortopathy phenotype as a predictor of aortic mechanics in patients with bicuspid valve},
  journal = {The Journal of Thoracic and Cardiovascular Surgery},
  year = {2025},
  doi = {10.1016/j.jtcvs.2023.12.018}
}
Kostenlos starten →