EUVIMEDDescoperă EUVIMED
Crossref

Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance

Xiaosong Hu iD, Yanwei Zhang, Yanan Li

Echocardiography · 2023

DOI: 10.1111/echo.15682 ↗

At a glance

Journal article in Echocardiography, 2023. Written by Xiaosong Hu and 2 co-authors. Institution: Department of Structural Heart Disease, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital, Central China Fuwai Hospital…. Major MEDLINE topics: Heart Septal Defects, Atrial, Septal Occluder Device, Echocardiography, Cardiac Catheterization. 19 references.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Introduction and Objectives Traditional transcatheter closure of atrial septal defect (ASD) via the femoral vein carries risk of radiation damage. Transcutaneous closure of ASD under echocardiography guidance avoids radiation exposure and can be gradually applied. An alternative is to transcutaneous closure of ASD trans‐jugular with an adjustable curved sheath under echocardiography guidance.

Methods

We retrospectively studied all cases of trans‐jugular transcutaneous closure of ASD with an adjustable curved sheath under echocardiography guidance in the Heart Center of Henan Province People's Hospital between 2016 and December 2022.

Results

A total of 156 patients were included, 74 males and 82 females. Mean age was 6.9 ± 7.4 years and weight 23.7 ± 14.6 kg. Mean sizes of the ASD and occluder were (9.7 ± 4.7) mm and (14.1 ± 5.7) mm. The mean operation time was (49.6 ± 29.2) min. No complications such as atrioventricular block, reoperation, or pericardial effusion occurred. There are 3 patients had a residual shunt. All patients were followed‐up for (38.7 ± 11.0) months. The three patients with residual shunt had self‐closed at the 3–6–12 months follow‐up. There was no complication at follow‐up.

Conclusion

Trans‐jugular transcutaneous closure of ASD with adjustable curved sheath under echocardiography guidance is safe, effective and minimally invasive.

Subjects

MeSH terms (MEDLINE)

Heart Septal Defects, AtrialSeptal Occluder DeviceEchocardiographyCardiac CatheterizationJugular VeinsUltrasonography, InterventionalHumansMaleFemaleRetrospective StudiesChildTreatment OutcomeChild, Preschool

Author keywords

adjustable curved sheathatrial septal defect (ASD)echocardiography guidancetranscutaneous

Authors and institutions

  • Department of Structural Heart Disease, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital, Central China Fuwai Hospital of Zhengzhou University, People's Hospital of Zhengzhou University, Z…
  • Department of Cardiovascular Ultrasound, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital, Central China Fuwai Hospital of Zhengzhou University, People's Hospital of Zhengzhou University,…

ORCID profiles: Xiaosong Hu

Cite

APA

Hu, X., Zhang, Y., & Li, Y. (2023). Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance. Echocardiography. https://doi.org/10.1111/echo.15682

Vancouver

Hu X, Zhang Y, Li Y. Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance. Echocardiography. 2023. doi:10.1111/echo.15682

BibTeX
@article{Hu2023,
  author = {Hu, Xiaosong and Zhang, Yanwei and Li, Yanan},
  title = {Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance},
  journal = {Echocardiography},
  year = {2023},
  doi = {10.1111/echo.15682}
}
Start for free →