Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance
Echocardiography · 2023
DOI: 10.1111/echo.15682 ↗Kurz gefasst
Fachartikel in der Zeitschrift Echocardiography, 2023. Verfasst von Xiaosong Hu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Structural Heart Disease, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital, Central China Fuwai Hospital…. Hauptthemen laut MEDLINE: Heart Septal Defects, Atrial, Septal Occluder Device, Echocardiography, Cardiac Catheterization. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Introduction and Objectives Traditional transcatheter closure of atrial septal defect (ASD) via the femoral vein carries risk of radiation damage. Transcutaneous closure of ASD under echocardiography guidance avoids radiation exposure and can be gradually applied. An alternative is to transcutaneous closure of ASD trans‐jugular with an adjustable curved sheath under echocardiography guidance.
Methods
We retrospectively studied all cases of trans‐jugular transcutaneous closure of ASD with an adjustable curved sheath under echocardiography guidance in the Heart Center of Henan Province People's Hospital between 2016 and December 2022.
Results
A total of 156 patients were included, 74 males and 82 females. Mean age was 6.9 ± 7.4 years and weight 23.7 ± 14.6 kg. Mean sizes of the ASD and occluder were (9.7 ± 4.7) mm and (14.1 ± 5.7) mm. The mean operation time was (49.6 ± 29.2) min. No complications such as atrioventricular block, reoperation, or pericardial effusion occurred. There are 3 patients had a residual shunt. All patients were followed‐up for (38.7 ± 11.0) months. The three patients with residual shunt had self‐closed at the 3–6–12 months follow‐up. There was no complication at follow‐up.
Conclusion
Trans‐jugular transcutaneous closure of ASD with adjustable curved sheath under echocardiography guidance is safe, effective and minimally invasive.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Structural Heart Disease, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital, Central China Fuwai Hospital of Zhengzhou University, People's Hospital of Zhengzhou University, Z…
- Department of Cardiovascular Ultrasound, Fuwai Central China Cardiovascular Hospital, Henan Provincial People's Hospital, Central China Fuwai Hospital of Zhengzhou University, People's Hospital of Zhengzhou University,…
ORCID-Profile: Xiaosong Hu
Zitieren
APA
Hu, X., Zhang, Y., & Li, Y. (2023). Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance. Echocardiography. https://doi.org/10.1111/echo.15682
Vancouver
Hu X, Zhang Y, Li Y. Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance. Echocardiography. 2023. doi:10.1111/echo.15682
BibTeX
@article{Hu2023,
author = {Hu, Xiaosong and Zhang, Yanwei and Li, Yanan},
title = {Trans‐jugular transcutaneous closure of atrial septal defects with an adjustable curved sheath under echocardiography guidance},
journal = {Echocardiography},
year = {2023},
doi = {10.1111/echo.15682}
}
EUVIMED