International clinical opinion on transparency, standardisation, and calibration alignment in the performance evaluation of systems for continuous glucose monitoring

John S Pemberton iD, Robert C Andrews, Katharine Barnard-Kelly, Tadej Battelino iD, Thomas Danne iD, Lutz Heinemann, Partha Kar, Alistair Lumb, David M Maahs, Julia K Mader iD, Chantal Mathieu iD, Viswanathan Mohan und 9 weitere

Diabetes, Obesity and Metabolism · 2026-04 · 28 (4) · 2551-2565

DOI: 10.1111/dom.70460 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Diabetes, Obesity and Metabolism, online erschienen am 26.01.2026. Verfasst von John S Pemberton und 20 weiteren Autor:innen. Beteiligte Einrichtung: Birmingham Women's and Children's NHS Foundation Trust, Birmingham, UK. Hauptthemen laut MEDLINE: Continuous Glucose Monitoring, Blood Glucose, Diabetes Mellitus, Type 1, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous glucose monitoring (CGM) is now central to diabetes management, yet variation in how respective medical products are evaluated limits meaningful comparison between CGM systems. Three barriers currently constrain reliable interpretation of glucose‐derived measures. The first is limited transparency: in several regulatory settings, particularly those using Conformité Européenne marking, clinical‐study reports, reference‐method information and analytical documentation required for market authorisation are not publicly accessible. The second barrier is heterogeneity in study procedures. Existing evaluations use different reference‐glucose methods, sampling strategies, glucose‐manipulation protocols and participant characteristics, leading to accuracy estimates that cannot be interpreted consistently across systems. The third barrier is calibration alignment. Even with full transparency and aligned procedures, CGM systems may differ because their calibration algorithms are trained on distinct reference‐glucose datasets, influencing reported glucose ranges, automated insulin‐delivery behaviour and interpretation during device transitions. A modified Delphi process involving clinicians, laboratory scientists, and researchers identified these issues as the principal determinants of comparability. During this process, the International Federation of Clinical Chemistry and Laboratory Medicine released a validated framework for performance evaluation of CGM systems, providing a unified approach to reference‐method selection, dynamic in‐clinic testing, and structured reporting. Adoption would reduce procedural variability but does not resolve calibration‐alignment differences. This international clinical opinion proposes a pathway towards internationally interpretable CGM evaluation: immediate transparency of clinical evidence, routine declaration of calibration alignment, and progressive adoption of validated standardised procedures. These steps provide a foundation for reliable interpretation and globally comparable assessment of CGM technologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Continuous Glucose MonitoringBlood GlucoseDiabetes Mellitus, Type 1Blood Glucose Self-MonitoringHumansCalibrationReference StandardsInsulin Infusion SystemsInsulinHypoglycemic AgentsReproducibility of Results

Substanzen

Blood GlucoseInsulinHypoglycemic Agents

Autor:innen und Institutionen

  • Birmingham Women's and Children's NHS Foundation Trust, Birmingham, UK.
  • University of Exeter Medical School, Exeter, UK.
  • NIHR Exeter Clinical Research Facility, Exeter, UK.
  • Barnard Health Research, Southampton, UK.
  • Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia.
  • University Medical Center Ljubljana, Ljubljana, Slovenia.

ORCID-Profile: John S Pemberton, Tadej Battelino, Thomas Danne, Julia K Mader, Chantal Mathieu, Dessi P Zaharieva

Zitieren

APA

Pemberton, J. S., Andrews, R. C., Barnard-Kelly, K., Battelino, T., Danne, T., Heinemann, L., Kar, P., Lumb, A., Maahs, D. M., Mader, J. K., Mathieu, C., Mohan, V., Murphy, H. R., Scott, E. M., Sherr, J. L., Smart, C. E., Tauschmann, M., Williams, A., Wilmot, E. G., …, & Moser, O. (2026). International clinical opinion on transparency, standardisation, and calibration alignment in the performance evaluation of systems for continuous glucose monitoring. Diabetes, Obesity and Metabolism, 28(4), 2551-2565. https://doi.org/10.1111/dom.70460

Vancouver

Pemberton JS, Andrews RC, Barnard-Kelly K, Battelino T, Danne T, Heinemann L, et al. International clinical opinion on transparency, standardisation, and calibration alignment in the performance evaluation of systems for continuous glucose monitoring. Diabetes, Obesity and Metabolism. 2026;28(4):2551-2565. doi:10.1111/dom.70460

BibTeX
@article{Pemberton2026,
  author = {Pemberton, John S and Andrews, Robert C and Barnard-Kelly, Katharine and Battelino, Tadej and Danne, Thomas and Heinemann, Lutz and Kar, Partha and Lumb, Alistair and Maahs, David M and Mader, Julia K and Mathieu, Chantal and Mohan, Viswanathan and Murphy, Helen R and Scott, Eleanor M and Sherr, Jennifer L and Smart, Carmel E and Tauschmann, Martin and Williams, Amanda and Wilmot, Emma G and Zaharieva, Dessi P and Moser, Othmar},
  title = {International clinical opinion on transparency, standardisation, and calibration alignment in the performance evaluation of systems for continuous glucose monitoring},
  journal = {Diabetes, Obesity and Metabolism},
  year = {2026},
  volume = {28},
  number = {4},
  pages = {2551--2565},
  doi = {10.1111/dom.70460}
}
Kostenlos starten →