Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range
Diabetic Medicine · 2025
DOI: 10.1111/dme.70137 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Diabetic Medicine, 2025. Verfasst von Roland H Stimson und 9 weiteren Autor:innen. Beteiligte Einrichtung: Edinburgh Centre for Endocrinology & Diabetes, NHS Lothian, Edinburgh, UK. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Blood Glucose Self-Monitoring, Insulin, Blood Glucose. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aims
This study aimed to assess the impact of the Omnipod 5 automated insulin delivery (AID) system on continuous glucose monitoring (CGM) metrics, HbA1c, and weight in a real‐world setting. Additionally, independent predictors of glycaemic response were assessed.
Methods
Observational analysis of adults with type 1 diabetes using Omnipod 5 ( n = 353). Paired data on CGM metrics ( n = 268), HbA1c ( n = 193), and weight ( n = 173) were collected at baseline and compared after median of 191, 120, and 221 days, respectively. Independent predictors of TIR response (≥5%) and HbA1c (≥5 mmol/mol) were assessed.
Results
Omnipod 5 use was associated with improved TIR (+16%, p < 0.001) and a reduction in HbA1c (−3 mmol/mol, p < 0.001). The greatest improvements (−7 mmol/mol, p < 0.001) were observed in individuals with elevated baseline HbA1c (≥58 mmol/mol). Sensor choice (Dexcom G6 vs. Freestyle Libre 2 Plus) influenced time in full auto mode (94% vs. 96%, p < 0.001) but did not affect the likelihood of improved TIR or HbA1c. Logistic regression identified baseline HbA1c (OR 1.24 per mmol/mol, p < 0.001) as the main association with improved HbA1c. Similarly, baseline TIR was associated with improvement in TIR (OR 0.83 per %, p < 0.001). Greater time in automation and using the lowest glucose target were also associated with improved outcomes.
Conclusions
Omnipod 5 is associated with significant and sustained improvements in CGM metrics and HbA1c, particularly in individuals with higher baseline HbA1c. The results suggest the potential benefits of prioritizing AID for individuals at greatest risk of complications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Edinburgh Centre for Endocrinology & Diabetes, NHS Lothian, Edinburgh, UK.
- University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, UK.
ORCID-Profile: Shareen Forbes, Fraser W Gibb
Zitieren
APA
Stimson, R. H., Strachan, M. W. J., Forbes, S., Wright, R. J., Mackenzie, S. D., McRobert, G., McMurray, E. M., Lyall, M. J., Dover, A. R., & Gibb, F. W. (2025). Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range. Diabetic Medicine. https://doi.org/10.1111/dme.70137
Vancouver
Stimson RH, Strachan MWJ, Forbes S, Wright RJ, Mackenzie SD, McRobert G, et al. Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range. Diabetic Medicine. 2025. doi:10.1111/dme.70137
BibTeX
@article{Stimson2025,
author = {Stimson, Roland H and Strachan, Mark W J and Forbes, Shareen and Wright, Rohana J and Mackenzie, Scott D and McRobert, Gayle and McMurray, Emily M and Lyall, Marcus J and Dover, Anna R and Gibb, Fraser W},
title = {Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range},
journal = {Diabetic Medicine},
year = {2025},
doi = {10.1111/dme.70137}
}
EUVIMED