EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range

Roland H Stimson, Mark W J Strachan, Shareen Forbes iD, Rohana J Wright, Scott D Mackenzie, Gayle McRobert, Emily M McMurray, Marcus J Lyall, Anna R Dover, Fraser W Gibb iD

Diabetic Medicine · 2025

DOI: 10.1111/dme.70137 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Diabetic Medicine, 2025. Verfasst von Roland H Stimson und 9 weiteren Autor:innen. Beteiligte Einrichtung: Edinburgh Centre for Endocrinology & Diabetes, NHS Lothian, Edinburgh, UK. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Blood Glucose Self-Monitoring, Insulin, Blood Glucose. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

This study aimed to assess the impact of the Omnipod 5 automated insulin delivery (AID) system on continuous glucose monitoring (CGM) metrics, HbA1c, and weight in a real‐world setting. Additionally, independent predictors of glycaemic response were assessed.

Methods

Observational analysis of adults with type 1 diabetes using Omnipod 5 ( n = 353). Paired data on CGM metrics ( n = 268), HbA1c ( n = 193), and weight ( n = 173) were collected at baseline and compared after median of 191, 120, and 221 days, respectively. Independent predictors of TIR response (≥5%) and HbA1c (≥5 mmol/mol) were assessed.

Results

Omnipod 5 use was associated with improved TIR (+16%, p < 0.001) and a reduction in HbA1c (−3 mmol/mol, p < 0.001). The greatest improvements (−7 mmol/mol, p < 0.001) were observed in individuals with elevated baseline HbA1c (≥58 mmol/mol). Sensor choice (Dexcom G6 vs. Freestyle Libre 2 Plus) influenced time in full auto mode (94% vs. 96%, p < 0.001) but did not affect the likelihood of improved TIR or HbA1c. Logistic regression identified baseline HbA1c (OR 1.24 per mmol/mol, p < 0.001) as the main association with improved HbA1c. Similarly, baseline TIR was associated with improvement in TIR (OR 0.83 per %, p < 0.001). Greater time in automation and using the lowest glucose target were also associated with improved outcomes.

Conclusions

Omnipod 5 is associated with significant and sustained improvements in CGM metrics and HbA1c, particularly in individuals with higher baseline HbA1c. The results suggest the potential benefits of prioritizing AID for individuals at greatest risk of complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes Mellitus, Type 1Blood Glucose Self-MonitoringInsulinBlood GlucoseInsulin Infusion SystemsHypoglycemic AgentsHumansFemaleMaleAdultGlycated HemoglobinMiddle AgedGlycemic ControlContinuous Glucose Monitoring

Stichwörter der Autor:innen

CSIIcontinuous glucose monitoringinsulin therapytype 1 diabetes

Substanzen

InsulinBlood GlucoseGlycated HemoglobinHypoglycemic Agentshemoglobin A1c protein, human

Autor:innen und Institutionen

  • Edinburgh Centre for Endocrinology & Diabetes, NHS Lothian, Edinburgh, UK.
  • University/BHF Centre for Cardiovascular Science, Queen's Medical Research Institute, University of Edinburgh, Edinburgh, UK.

ORCID-Profile: Shareen Forbes, Fraser W Gibb

Zitieren

APA

Stimson, R. H., Strachan, M. W. J., Forbes, S., Wright, R. J., Mackenzie, S. D., McRobert, G., McMurray, E. M., Lyall, M. J., Dover, A. R., & Gibb, F. W. (2025). Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range. Diabetic Medicine. https://doi.org/10.1111/dme.70137

Vancouver

Stimson RH, Strachan MWJ, Forbes S, Wright RJ, Mackenzie SD, McRobert G, et al. Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range. Diabetic Medicine. 2025. doi:10.1111/dme.70137

BibTeX
@article{Stimson2025,
  author = {Stimson, Roland H and Strachan, Mark W J and Forbes, Shareen and Wright, Rohana J and Mackenzie, Scott D and McRobert, Gayle and McMurray, Emily M and Lyall, Marcus J and Dover, Anna R and Gibb, Fraser W},
  title = {Impact of Omnipod 5 automated insulin delivery on continuous glucose monitoring metrics and predictors of improvement in time in range},
  journal = {Diabetic Medicine},
  year = {2025},
  doi = {10.1111/dme.70137}
}
Kostenlos starten →