Seasonal fluctuations of CGM metrics in individuals with type 1 diabetes using an intermittently scanned CGM device or sensor augmented pump
Endocrine · 2024
DOI: 10.1007/s12020-024-03971-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endocrine, 2024. Verfasst von Yuka Oi-Yo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Diabetes and Endocrinology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Seasons, Blood Glucose Self-Monitoring, Blood Glucose. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Diabetes mellitus
Abstract (Originalsprache)
Objective
To elucidate the fluctuations in glucose levels measured using CGM-metrics during the four distinct seasons of the year in individuals with type 1 diabetes mellitus (T1DM) using an intermittently scanned CGM (isCGM) device or sensor augmented pump (SAP). Research design and methods This retrospective, single-center study enrolled 93 individuals with T1DM who were equipped with an isCGM device or SAP at Kobe University Hospital. The subjects had a median age of 47.0 years [interquartile range, 37.0–62.0 years], 25 individuals (26.9%) were male, median body mass index was 22.0 kg/m 2 [20.8–23.8 kg/m 2 ], and median hemoglobin A 1c level was 7.4% [6.9–8.0%]. CGM data were reviewed from January to December 2019, and the mean sensor glucose (SG) value, time above range (TAR), time in range (TIR), time below range (TBR), and standard deviation (SD) of SG were calculated for each season (spring, March–May; summer, June–August; autumn, September–November; winter, December–February).
Results
Seasonal fluctuations were detected for mean SG, TAR, TIR, and SD, with TIR being lower and mean SG, TAR, and SD being higher in cold seasons (spring or winter) than in warm seasons (summer or autumn).
Conclusion
Seasonal fluctuations in CGM metrics should be taken into account in future studies performed to evaluate the favorable impact of CGM on glycemic management in individuals with T1DM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Diabetes and Endocrinology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
- Division of Diabetes and Endocrinology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan. hirota@med.kobe-u.ac.jp.
ORCID-Profile: Yushi Hirota
Zitieren
APA
Oi-Yo, Y., Urai, S., Yamamoto, A., Takayoshi, T., Yamamoto, M., Hirota, Y., & Ogawa, W. (2024). Seasonal fluctuations of CGM metrics in individuals with type 1 diabetes using an intermittently scanned CGM device or sensor augmented pump. Endocrine. https://doi.org/10.1007/s12020-024-03971-5
Vancouver
Oi-Yo Y, Urai S, Yamamoto A, Takayoshi T, Yamamoto M, Hirota Y, et al. Seasonal fluctuations of CGM metrics in individuals with type 1 diabetes using an intermittently scanned CGM device or sensor augmented pump. Endocrine. 2024. doi:10.1007/s12020-024-03971-5
BibTeX
@article{OiYo2024,
author = {Oi-Yo, Yuka and Urai, Shin and Yamamoto, Akane and Takayoshi, Tomofumi and Yamamoto, Masaaki and Hirota, Yushi and Ogawa, Wataru},
title = {Seasonal fluctuations of CGM metrics in individuals with type 1 diabetes using an intermittently scanned CGM device or sensor augmented pump},
journal = {Endocrine},
year = {2024},
doi = {10.1007/s12020-024-03971-5}
}