The efficacy of intermittent scanning continuous glucose monitoring in the elderly: A case–control study
Diabetes, Obesity and Metabolism · 2025
DOI: 10.1111/dom.16417 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Diabetes, Obesity and Metabolism, 2025. Verfasst von Riemer A Been und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endocrinology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. Hauptthemen laut MEDLINE: Blood Glucose Self-Monitoring, Blood Glucose, Glycemic Control, Diabetes Mellitus, Type 2. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: European Foundation for the Study of Diabetes (EFSD).
Abstract (Originalsprache)
Aims
The efficacy of intermittently scanning continuous glucose monitoring (is‐CGM) technology among elderly people with diabetes mellitus (DM) has been understudied. We investigated if the initiation of is‐CGM results in improved glycemic control among this population. Materials and Methods Retrospective, observational case–control study. Cases were selected randomly from the DM outpatient clinic of the University Medical Center Groningen between 2015 and 2022 if they had type 1 or type 2 DM, were registered users of is‐CGM devices and were aged 60 or older at initiation of those devices. They were matched to randomly selected controls with no CGM usage based on age, gender, DM type and treatment type (insulin‐pen or pump). Data were collected at baseline, 6 months prior and 3, 6, 9, 12 and 24 months after initiation. Linear mixed‐effects regression was performed to assess the effects of is‐CGM usage on HbA1c.
Results
Three hundred and fifty‐three participants were analysed (142 cases, 211 controls). Median HbA1c at baseline for is‐CGM users was 8.00% [7.20%–9.10%] and for controls 7.90% [7.10%–8.70%]. Unadjusted analysis showed significant reductions of HbA1c 3 months after initialization (cases vs. controls, −0.50% vs. −0.02%, p = 0.016), persisting throughout the study. Adjusting for confounders, is‐CGM initiation resulted in significant HbA1c reductions after 6 months (−0.29%, p = 0.006) up until 24 months (−0.39%, p = 0.033). The rate of sensor discontinuation was 2.8%.
Conclusions
The use of is‐CGM improves glycemic control in elderly (≥60 years old) persons with DM after 3 months, and this persists for at least 24 months. The number of discontinuations is low. This data emphasizes the positive impact of is‐CGM on the elderly population with DM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Endocrinology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Department of Mathematics, University of Groningen, Groningen, The Netherlands.
- Department of Mathematics, Bernoulli Institute, University of Groningen, Groningen, The Netherlands.
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Department of Neurosurgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
- Department of Internal Medicine, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
ORCID-Profile: Riemer A Been, Peter R van Dijk
Förderung
- European Foundation for the Study of Diabetes (EFSD)
Zitieren
APA
Been, R. A., van Helsdingen, M. R. X., Zammit, D., Grzegorczyk, M., Krijnen, W. P., Tamasi, K., Gans, R. O. B., van Beek, A. P., & van Dijk, P. R. (2025). The efficacy of intermittent scanning continuous glucose monitoring in the elderly: A case–control study. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.16417
Vancouver
Been RA, van Helsdingen MRX, Zammit D, Grzegorczyk M, Krijnen WP, Tamasi K, et al. The efficacy of intermittent scanning continuous glucose monitoring in the elderly: A case–control study. Diabetes, Obesity and Metabolism. 2025. doi:10.1111/dom.16417
BibTeX
@article{Been2025,
author = {Been, Riemer A and van Helsdingen, Max R X and Zammit, Darren and Grzegorczyk, Marco and Krijnen, Wim P and Tamasi, Katalin and Gans, Rijk O B and van Beek, André P and van Dijk, Peter R},
title = {The efficacy of intermittent scanning continuous glucose monitoring in the elderly: A case–control study},
journal = {Diabetes, Obesity and Metabolism},
year = {2025},
doi = {10.1111/dom.16417}
}
EUVIMED