EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Insulin delivery characteristics and glycemic control in older adults with type 1 diabetes using the Minimed™ 780G system: a real-world analysis

Špela Volčanšek, Petra Vidmar, Andrej Janež, Aleš Skvarča

Frontiers in Endocrinology · 07.08.2026 · 17

DOI: 10.3389/fendo.2026.1910192 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Endocrinology, online erschienen am 07.08.2026. Verfasst von Špela Volčanšek und 3 weiteren Autor:innen. Beteiligte Einrichtung: University Medical Centre Ljubljana, Department of Endocrinology, Diabetes and Metabolic Diseases, Ljubljana, Slovenia. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Insulin, Glycemic Control, Hypoglycemic Agents. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Univerza v Ljubljani.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Diabetes self-management in older adults with type 1 diabetes (T1D) presents a unique clinical challenge, since maintaining tight glycemic control must be carefully weighed against age-related vulnerabilities. This study aimed to analyze glycemic control through the effects of customized algorithm settings in a cohort of older adults with T1D using an automated insulin delivery (AID) system.

Methods

This retrospective real-world data analysis included users of the MiniMed™ 780G AID system, aged ≥60 years. Continuous glucose monitoring (CGM) data including time in range (TIR; 70–180 mg/dL; 3.9–10.0 mmol/L), time in tight range (TITR; 70–140 mg/dL; 3.9–7.8 mmol/L), time below range (TBR; <70 mg/dL; <3.9 mmol/L), level 2 TBR (<54 mg/dL; <3.0 mmol/L) and time above range (TAR; >180 mg/dL; >10.0 mmol/L) were analyzed alongside algorithm settings and daily insulin use. Group comparisons utilized standard parametric and non-parametric statistical tests. A multivariable logistic regression model identified independent clinical predictors of high glycemic performance (TITR ≥50%).

Results

The cohort comprised 97 AID users (70.1% female, mean age 67.9 ± 6.7; range 60–90 years). Overall glycemic control was good, with mean TIR 76.1%, TITR 51.1% and TBR 1.1%. Fourteen participants (14.4%) used the manufacturer’s recommended optimal settings (ROS); i.e., target glucose of 5.5 mmol/L and active insulin time of 2 hours. CGM metrics did not differ between ROS and non-ROS users for TIR, TITR and TBR. When stratifying the cohort by glycemic performance, 55 participants (56.7%) reached TITR ≥50%; however, the adoption of ROS in high (≥50%) TITR and lower (<50%) TITR subgroups was similar (16.4% vs 11.9%; Fisher p=0.58). When compared to the lower TITR subgroup, participants in the high TITR subgroup delivered less auto-correction insulin (14.2% vs 20.6%, p<0.001) and a higher proportion of manual bolus insulin (46.1% vs 35.2%, p<0.001), which remained a significant predictor of high TITR after multivariable adjustment. TBR was significantly higher in the high (≥50%) TITR subgroup, although it remained low in absolute terms (1.5% vs. 0.8%; p=0.017).

Conclusion

While the MiniMed™ 780G AID system use is associated with low CGM-derived hypoglycemia exposure and highly effective glycemic control, regardless of customized settings, superior glycemic control is associated with a higher proportion of user-initiated manual boluses. The algorithm supports, but cannot replace, user engagement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes Mellitus, Type 1InsulinGlycemic ControlHypoglycemic AgentsInsulin Infusion SystemsHumansFemaleRetrospective StudiesContinuous Glucose MonitoringAgedMaleBlood GlucoseMiddle AgedAlgorithmsBlood Glucose Self-Monitoring

Stichwörter der Autor:innen

advanced technologiesautomated insulin deliveryhypoglycemiaindividualized careolder adultsreal-world datatime in tight rangetype 1 diabetes

Substanzen

InsulinHypoglycemic AgentsBlood Glucose

Autor:innen und Institutionen

  • University Medical Centre Ljubljana, Department of Endocrinology, Diabetes and Metabolic Diseases, Ljubljana, Slovenia.
  • Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia.

Förderung

  • Univerza v Ljubljani

Zitieren

APA

Volčanšek, Š., Vidmar, P., Janež, A., & Skvarča, A. (2026). Insulin delivery characteristics and glycemic control in older adults with type 1 diabetes using the Minimed™ 780G system: a real-world analysis. Frontiers in Endocrinology, 17. https://doi.org/10.3389/fendo.2026.1910192

Vancouver

Volčanšek Š, Vidmar P, Janež A, Skvarča A. Insulin delivery characteristics and glycemic control in older adults with type 1 diabetes using the Minimed™ 780G system: a real-world analysis. Frontiers in Endocrinology. 2026;17. doi:10.3389/fendo.2026.1910192

BibTeX
@article{Volanek2026,
  author = {Volčanšek, Špela and Vidmar, Petra and Janež, Andrej and Skvarča, Aleš},
  title = {Insulin delivery characteristics and glycemic control in older adults with type 1 diabetes using the Minimed™ 780G system: a real-world analysis},
  journal = {Frontiers in Endocrinology},
  year = {2026},
  volume = {17},
  doi = {10.3389/fendo.2026.1910192}
}
Kostenlos starten →